首页> 外文期刊>Medical Devices: Evidence and Research >Cutting a mediolateral episiotomy at the correct angle: evaluation of a new device, the Episcissors-60
【24h】

Cutting a mediolateral episiotomy at the correct angle: evaluation of a new device, the Episcissors-60

机译:以正确的角度切开前外侧巩膜切开术:评估一种新设备Episcissors-60

获取原文
           

摘要

Background: Anal incontinence is nine times more prevalent in women than in men due to obstetric anal sphincter injury (OASI). OASI is linked to midline episiotomies and mediolateral episiotomies with post-delivery angles of 60 degrees. Studies show that doctors and midwives are unable to correctly "eyeball" the safe angle required due to perineal stretching by the fetal head at crowning. A new scissor instrument (Episcissors-60) was devised to allow cutting a mediolateral episiotomy at a fixed angle of 60 degrees from the perineal midline.Methods: Scissors with a marker guide limb pointing towards the anus were devised, ensuring an angle of 60 degrees between the scissor blades and the guide limb. This device was initially tested in models. Post-delivery angles were recorded on transparencies and analyzed by an author blinded to clinical details. Accoucheurs were asked to rate the ease of use on a 5-point scale.Results: Of the 17 women, 14 delivered with ventouse, two with forceps, and one with sequential ventouse–forceps. Indications for instrumental delivery were suboptimal cardiotocogram and/or prolonged second stage of labor. Mean birth weight was 3.41 (2.92–4.12) kg. A mean post-delivery angle of 42.4±7 (range 30–60, median 43) degrees (95% confidence interval 38.8–46) was achieved with the Episcissors-60 instrument. Eighty-eight percent of clinicians agreed or strongly agreed that the scissors were easy to use.Conclusion: The Episcissors-60 delivered a consistent post-delivery angle of 43 degrees. They could replace "eyeballing" when performing mediolateral episiotomies and form part of a preventative strategy to reduce OASI.
机译:背景:由于产科肛门括约肌损伤(OASI),女性肛门失禁的发生率是男性的九倍。 OASI与分娩后角度为60度的中线癫痫和中外侧癫痫联系在一起。研究表明,医生和助产士不能正确地“眼球”化,因为在加冠时胎儿头部会阴拉伸。设计了一种新的剪刀器械(Episcissors-60),以允许从会阴中线以60度的固定角度切开前外侧巩膜切开术。方法:设计了带有标记引导肢指向肛门的剪刀,确保角度为60度在剪刀刀片和导向臂之间。该设备最初在模型中进行了测试。分娩后的角度记录在透明胶片上,并由对临床细节不知情的作者进行分析。结果要求参加者以5分制进行评分。结果:在这17名妇女中,有14例有腹膜分娩,两名是用钳子分娩,而一名则是先后使用腹膜钳。器械分娩的指征是心电图欠佳和/或第二产程延长。平均出生体重为3.41(2.92-4.12)千克。使用Episcissors-60仪器,平均分娩后角度为42.4±7(范围30–60,中位数43)(95%置信区间38.8–46)。 88%的临床医生同意或强烈同意剪刀易于使用。结论:Episcissors-60的交付后角始终保持43度。他们可以在进行中外侧切除术时取代“眼球”,并成为减少OASI的预防策略的一部分。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号