首页> 外文期刊>Atmospheric Measurement Techniques >Comparison of profile total ozone from SBUV (v8.6) with GOME-type and ground-based total ozone for a 16-year period (1996 to 2011)
【24h】

Comparison of profile total ozone from SBUV (v8.6) with GOME-type and ground-based total ozone for a 16-year period (1996 to 2011)

机译:比较SBUV(v8.6)与GOME型和地面基总臭氧在16年内(1996年至2011年)的剖面总臭氧

获取原文
           

摘要

This paper describes the comparison of the variability of total column ozone inferred from the three independent multi-year data records, namely, (i) Solar Backscatter Ultraviolet Instrument (SBUV) v8.6 profile total ozone, (ii) GTO (GOME-type total ozone), and (iii) ground-based total ozone data records covering the 16-year overlap period (March 1996 through June 2011). Analyses are conducted based on area-weighted zonal means for 0–30° S, 0–30° N, 50–30° S, and 30–60° N. brbr It has been found that, on average, the differences in monthly zonal mean total ozone vary between ?0.3 and 0.8 % and are well within 1%. brbr For GTO minus SBUV, the standard deviations and ranges (maximum minus minimum) of the differences regarding monthly zonal mean total ozone vary between 0.6–0.7% and 2.8–3.8% respectively, depending on the latitude band. The corresponding standard deviations and ranges regarding the differences in monthly zonal mean anomalies show values between 0.4–0.6% and 2.2–3.5%. The standard deviations and ranges of the differences ground-based minus SBUV regarding both monthly zonal means and anomalies are larger by a factor of 1.4–2.9 in comparison to GTO minus SBUV. brbr The ground-based zonal means demonstrate larger scattering of monthly data compared to satellite-based records. The differences in the scattering are significantly reduced if seasonal zonal averages are analyzed. brbr The trends of the differences GTO minus SBUV and ground-based minus SBUV are found to vary between ?0.04 and 0.1% yrsup?1/sup (?0.1 and 0.3 DU yrsup?1/sup). These negligibly small trends have provided strong evidence that there are no significant time-dependent differences among these multi-year total ozone data records. brbr Analyses of the annual deviations from pre-1980 level indicate that, for the 15-year period of 1996 to 2010, all three data records show a gradual increase at 30–60° N from ?5% in 1996 to ?2% in 2010. In contrast, at 50–30° S and 30° S–30° N there has been a levelling off in the 15 years after 1996. The deviations inferred from GTO and SBUV show agreement within 1%, but a slight increase has been found in the differences during the period 1996–2010.
机译:本文描述了从三个独立的多年数据记录推断出的总柱状臭氧变化的比较,这些记录是:(i)太阳背散射紫外线仪(SBUV)v8.6剖面总臭氧量;(ii)GTO(GOME型总臭氧),以及(iii)涵盖16年重叠期(1996年3月至2011年6月)的地面臭氧总数据记录。基于区域加权的区域平均法对0–30°S,0–30°N,50–30°S和30–60°N进行分析。 已经发现,平均而言,月度平均臭氧总量的差异介于0.3%和0.8%之间,并且在1%以内。 对于GTO减去SBUV,月平均纬向臭氧总量的差异的标准偏差和范围(最大减去最小值)分别在0.6-0.7%和2.8-3.8%之间,具体取决于纬度带。关于月度纬向平均距平差的相应标准偏差和范围显示值在0.4-0.6%和2.2-3.5%之间。与GTO减去SBUV相比,基于地面的负SBUV的月度纬向平均值和异常的标准偏差和差异范围要大1.4-2.9倍。 与基于卫星的记录相比,基于地面的分区手段显示每月数据的分散性更大。如果分析季节性纬向平均数,则散射差异将大大减少。 发现GTO负SBUV和地面负SBUV的差异趋势在0.04和0.1%yr ?1 之间变化(0.1和0.3 DU yr ?1 )。这些微不足道的小趋势提供了有力的证据,表明这些多年的臭氧总量数据记录之间没有明显的时间相关差异。 对1980年前水平的年偏差的分析表明,在1996年至2010年的15年中,所有三个数据记录都表明,在30-60°N处从1996年的5%逐渐增加。到2010年降至2%。相比之下,在1996年之后的15年中,在南纬50–30°和南北30°–30°处趋于平稳。从GTO和SBUV推算得出的偏差在1%以内,但在1996年至2010年期间,差异有所增加。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号