首页> 外文期刊>Advance journal of food science and technology >Effect of Ventilation Tube Diameter on Thermal Performance of Food Refrigerated Warehouse Floor Antifreezing Mechanical Ventilation System
【24h】

Effect of Ventilation Tube Diameter on Thermal Performance of Food Refrigerated Warehouse Floor Antifreezing Mechanical Ventilation System

机译:通风管直径对食品冷藏库地板防冻机械通风系统热性能的影响

获取原文
           

摘要

To investigate the effect of ventilation tube inside diameter on thermal performance of food refrigerated warehouse floor ant freezing mechanical ventilation system, a steady three-dimensional mathematical model of heat transfer is set up in this study. The calculation conditions of the heat transfer model are defined according to the reasonable simplification and heat transfer process. The temperature fields of this system are simulated and calculated by CFD software PHOENICS under different tube inside diameters, 250 or 300 mm. The results show that the effect of ventilation tube inside diameter is greater on thermal performance of food refrigerated warehouse floor antifreezing mechanical ventilation system. The proper tube inside diameter is pointed to be 250 mm for the food refrigerated warehouse floor with 1.5 m tube spacing.
机译:为了研究通风管内径对食品冷藏仓库地面蚂蚁冷冻机械通风系统热性能的影响,建立了稳定的三维传热数学模型。根据合理的简化和传热过程,定义了传热模型的计算条件。该系统的温度场由CFD软件PHOENICS在不同的管内径250或300 mm下进行模拟和计算。结果表明,通风管内径对食品冷藏库地板防冻机械通风系统的热性能影响较大。对于食品冷藏仓库地板,管间距为1.5 m,正确的管内直径应为250 mm。