首页> 外文期刊>Bulletin of Emergency and Trauma >Diagnostic Accuracy of Rapid Ultrasound in Shock (RUSH) Exam; A Systematic Review and Meta-analysis
【24h】

Diagnostic Accuracy of Rapid Ultrasound in Shock (RUSH) Exam; A Systematic Review and Meta-analysis

机译:快速超声冲击检查(RUSH)的诊断准确性;系统评价和荟萃分析

获取原文
           

摘要

Objective: To perform a diagnostic accuracy of the rapid ultrasound in shock (RUSH) to diagnose the etiology of undifferentiated shock in patients presenting to the emergency department (ED).Methods: We searched the Medline via PubMed, Scopus, and ISI Web of Knowledge till July 2017. Two independent reviewers screened studies for eligibility. Our study analysis is planned in accordance with the guidelines for metaa??analysis of diagnostic studies. In the systematic search, of 397 references, 295 were excluded on the basis of the title and abstract. For the remaining 102 articles, the full text was retrieved and critically reviewed. After the selection process, five papers were included.Results: The pooled estimate of all data showed that the RUSH protocol exhibited high sensitivity (0.87, 95% Confidence Interval (CI): 0.80-0.92, I2 = 46.7%) and specificity (0.98, 95% C. I.: 0.96-0.99, I2 = 30.8%). The AUC for SROC, a global measure of the RUSH protocol performance, was 0.98 ?± 0.01, indicates the high accuracy of the test. Positive and negative likelihood ratios reported from the studies ranged from 9.83 to 51.32 and 0.04 to 0.33, respectively. The pooled estimate of all data showed that the RUSH protocol exhibited high positive likelihood ratio (19.19, 95% C. I.: 11.49-32.06, I2 = 14.1%) and low negative likelihood ratio (0.23, 95% C. I.: 0.15-0.34, I2 = 18.4%).Conclusion: This meta-analysis suggests that RUSH protocol has generally good role to distinguish the states of shock in patients with undifferentiated shock referred to the emergency department.
机译:目的:提高对休克快速超声(RUSH)的诊断准确性,以诊断急诊科(ED)患者未分化休克的病因。方法:我们通过PubMed,Scopus和ISI搜索了Medline直至2017年7月。两名独立审核者筛选了研究的资格。我们的研究分析是根据诊断研究的荟萃分析的指南计划的。在系统搜索中,根据标题和摘要,在397篇参考文献中排除了295篇。对于其余的102篇文章,全文被检索并进行了严格审查。选择过程之后,包括五篇论文。结果:所有数据的汇总估计表明,RUSH方案显示出高灵敏度(0.87,95%置信区间(CI):0.80-0.92,I2 = 46.7%)和特异性(0.98) ,95%CI:0.96-0.99,I2 = 30.8%)。 SROC的AUC(衡量RUSH协议性能的总体指标)为0.98±0.01,表明该测试的准确性很高。研究报告的正似然率和负似然率分别为9.83至51.32和0.04至0.33。所有数据的汇总估计表明,RUSH协议显示出高的正似然比(19.19,95%CI:11.49-32.06,I2 = 14.1%)和低的负似然比(0.23,95%CI:0.15-0.34,I2 = 18.4%)。结论:这项荟萃分析表明,RUSH协议在区分未分化电击患者的电击状态方面通常具有很好的作用,请转诊至急诊科。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号