摘要

Background To reduce injection pain and improve satisfaction, a thinner (29-gauge [29G]), sharper (5-bevel) needle than the 27G/3-bevel needle used previously to inject interferon (IFN) beta-1a, 44 or 22 mcg subcutaneously (sc) three times weekly (tiw), was developed for use in multiple sclerosis (MS). Methods Two clinical trials in healthy volunteers and five surveys of patients with MS were conducted to assess whether the 29G/5-bevel needle with a Thermo Plastic Elastomer (TPE) needle shield (a sleeve that houses the tip of the needle in a secure location) is an improvement over the 27G/3-bevel needle with a rubber shield for injection of IFN beta-1a, 44 or 22 mcg sc tiw. Parameters assessed were: pain and ease of insertion (healthy volunteer and nurse responses on subjective pain measurement scales); and patient satisfaction (surveys of patients with MS). Results In healthy volunteers, the 29G/5-bevel needle with TPE shield was associated with the least perceived pain on the Visual Analog Scale (VAS) and Verbal VAS (VB-VAS); mean VAS pain scores decreased by 40% and skin penetration improved by 69% compared with the 27G/3-bevel needle with standard rubber shield (p Conclusion Together these studies indicate that the 29G/5-bevel needle with the TPE shield is an improvement over the 27G/3-bevel needle with standard rubber shield in terms of pain, ease of insertion and patient satisfaction. These improvements are expected to result in improved compliance in patients with MS treated with IFN beta-1a, 44 or 22 mcg sc tiw.
机译:背景为了减轻注射疼痛并提高满意度,比以前用于注射干扰素(IFN)beta-1a,44或22的27G / 3锥针更细(29针[29G]),更尖锐的(5锥)针。每周三次(两次)皮下注射mcg,用于多发性硬化症(MS)。方法在健康志愿者中进行了两项临床试验,并对MS患者进行了五项调查,以评估29G / 5斜角针头是否装有热塑性弹性体(TPE)针头罩(将针头尖端固定在安全位置的套筒) )是对27G / 3斜面针头的改进,该针头带有橡胶护罩,用于注射IFNβ-1a,44或22 mcg sc tiw。评估的参数为:疼痛和插入的难易程度(健康的志愿者和护士对主观疼痛测量量表的反应);和患者满意度(MS患者的调查)。结果在健康志愿者中,带有TPE防护罩的29G / 5锥状针头与视觉模拟量表(VAS)和口头VAS(VB-VAS)上的疼痛感最少。与带有标准橡胶护罩的27G / 3-斜角针相比,平均VAS疼痛评分降低了40%,皮肤渗透率提高了69%(p结论这些研究共同表明,带有TPE护罩的29G / 5-斜角针是一种改善在疼痛,易于插入和患者满意度方面比标准橡胶护套的27G / 3斜面针头要好,这些改善有望改善IFN beta-1a,44或22 mcg sc tiw治疗的MS患者的依从性。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号