首页> 外文期刊>Dental materials >The effects of thermocycling on the flexural strength and flexural modulus of modem resin-based filling materials
【24h】

The effects of thermocycling on the flexural strength and flexural modulus of modem resin-based filling materials

机译:热循环对现代树脂基填充材料弯曲强度和弯曲模量的影响

获取原文
获取原文并翻译 | 示例
           

摘要

Objective. Evaluation of flexural strengths and flexural moduli of hybrids, packables, ormo- cers, compomers and flowables prior to, and after, thermocycling. Materials and methods. Twenty specimens, size (25 ± 2) mm x (2 ± 0.1) mm x (2 ± 0.1) mm, of Herculite (HE), Point 4 (P4), TetricCeram (TC), Miris (MI), TetricCeram HB, (HB), Solitaire 2 (SO), Surefil A (SU), Definte (DE), Admira (AD), Dyract AP (DY), Compoglass (CO) and TetricFlow (TF) were made according to ISO 4049. A three-point-bending test was carried out for the first 10 specimens after 24 h water storage at 37℃ and for the second 10 specimens after 30-day water storage at 37℃, followed by 5000 thermocycles between +5 and +55℃. For each test series flexural strengths and flexural moduli were calculated. Statistical significance was p < 0.05. Results. Flexural strengths of DY and CO missed the 80 MPa limit of ISO 4049 for occlusal fillings prior to and after thermocycling. AD missed it after thermocycling. HE, P4, TC, MI, HB, SO, SU, DE and TF did not significantly differ prior to and after thermocycling. Flexural strength of SO and AD significantly decreased after thermocycling. No change of the flexural moduli could be observed for any of the test materials. Only SU exceeded 10,000 MPa prior to and after thermocycling. Significance. Only DY and CO missed the flexural strength limit of ISO 4049 for occlusal fillings. Only SU exceeded a flexural modulus of 10,000 MPa prior to and after thermocycling.
机译:目的。在热循环之前和之后,评估杂化物,可包装物,有机物,复合物和可流动物的抗弯强度和弯曲模量。材料和方法。二十个标本(25±2)mm x(2±0.1)mm x(2±0.1)mm的标本,其样本为Herculite(HE),Point 4(P4),TetricCeram(TC),Miris(MI),TetricCeram HB, (HB),纸牌2(SO),Surefil A(SU),Definte(DE),Adira(AD),Dyract AP(DY),Compoglass(CO)和TetricFlow(TF)是根据ISO 4049制成的。对37℃下24小时储水后的前10个样品和37℃下30天储水后的后10个样品进行点弯曲试验,然后在+5至+ 55℃之间进行5000个热循环。对于每个测试系列,计算弯曲强度和弯曲模量。统计学显着性是p <0.05。结果。 DY和CO的抗弯强度未达到ISO 4049规定的热循环前后咬合充填的80 MPa极限。热循环后,AD错过了它。热循环前后,HE,P4,TC,MI,HB,SO,SU,DE和TF没有显着差异。热循环后,SO和AD的抗弯强度显着降低。对于任何测试材料,均未观察到弯曲模量的变化。热循环前后只有SU超过10,000 MPa。意义。只有DY和CO错过了咬合填充物的ISO 4049弯曲强度极限。在热循环之前和之后,只有SU超过10,000 MPa的弯曲模量。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号