摘要

Objectives: The effect of water sorption on the impact strengths of two preimpregnated fiber-reinforced composites (FRCs) and one impregnated FRC were studied. All FRCs were available clinically. Methods: Eight 1.0 mm x 2.0 mm x 25.0 mm bar-shaped specimens of each material were prepared according to manufacturers' instructions. The impact strength of each specimen was tested (adoption from ISO 179-1 Plastics—Determination of Charpy impact properties) after the specimens were immersed in 23.0 ? 1 ℃ distilled water for seven, 60 and 180 days. The data were analyzed using the Weibull method. Scanning electron micrographs were taken to examine the mode of failure. Results: Weibull analysis of the B10 strength of the FRCs showed that the difference in impact strength for each FRC due to the duration of water immersion was not significant (P > 0.05). The impact strength of preimpregnated E-glass FRC (Vectris) (75 kJ/m~2) was not significantly different from the preimpregnated S-glass FRC (FiberKor) (66 kJ/m~2) (P > 0.05). The impregnated FRC possessed impact strength (42 kJ/m~2) that was not significantly different from the preimpregnated S-glass FRC but was significantly lower than the preimpregnated E-glass FRC. x 100 SEMs of the three types of FRC specimens revealed fiber failure to be the predominant mode of failure. Significance: Water immersion up to 180 days duration did not significantly affect the impact strength of three FRCs. The impact strength of the impregnated FRC was not significantly different from the preimpregnated S-glass FRC but was significantly lower than the preimpregnated E-glass FRC.
机译:目的:研究了吸水率对两种预浸渍的纤维增强复合材料(FRC)和一种浸渍的FRC的冲击强度的影响。所有FRC均可在临床上获得。方法:根据制造商的说明准备每种材料的八个1.0毫米x 2.0毫米x 25.0毫米的棒状样品。将样品浸入23.0的溶液中后,测试每个样品的冲击强度(采用ISO 179-1塑料—夏比冲击性能的测定)。 1℃的蒸馏水持续7、60和180天。使用Weibull方法分析数据。扫描电子显微照片被用来检查失效模式。结果:对FRC的B10强度进行的Weibull分析表明,由于浸泡时间的长短,每个FRC的冲击强度差异均不显着(P> 0.05)。预先浸渍的E-玻璃FRC(Vectris)的冲击强度(75 kJ / m〜2)与预先浸渍的S-玻璃FRC(FiberKor)(66 kJ / m〜2)没有显着差异(P> 0.05)。浸渍后的FRC的冲击强度(42 kJ / m〜2)与预浸渍的S玻璃FRC并无显着差异,但明显低于预浸渍的E玻璃FRC。三种类型的FRC标本的x 100 SEM显示,光纤故障是故障的主要方式。启示:浸水长达180天并没有显着影响三个FRC的冲击强度。浸渍的FRC的冲击强度与预浸渍的S玻璃FRC并无显着差异,但显着低于预浸渍的E玻璃FRC。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号