Computer aided analysis of digitized dental stone replicas by dental CAD/CAM technology

机译:通过牙科CAD / CAM技术对数字化牙科石复制品进行计算机辅助分析

获取原文
获取原文并翻译 | 示例
           

摘要

Objectives. To determine the reproducibility of digitized dental stone replicas compared to the master model and the reliability of the computer aided analysis. Methods. Four master dies, prepared for complete crowns were fabricated in presintered yttria-stabilized tetragonal zirconia (Y-TZP). Eight vinyl polysiloxane impressions (PROVIL novo; Heraeus Kulzer) were taken of each die and stone replicas were poured in type IV stone (Vel-Mix Stone; Kerr). The master dies and the stone replicas were digitized in a touch-probe scanner (Procera? Forte; Nobel Biocare AB), to create triangulated surface-models. The point-cloud from the first of the repeated digitizations of each master die was used as CAD-reference-models (CRM). Discrepancies between the points in the triangulated surface-models and the corresponding CRM were measured by a matching-software (CopyCAD 6.504 SP2; Delcam Plc). The distribution of the discrepancies was analyzed and presented in color-difference-maps. Results. The precision of the measuring method, presented as the repeatability coefficient, ranged between 7 and 16 (xm (entire surface), whereas the analysis of the stone replicas revealed a precision (repeatability coefficient) ranging from 19 to 26 μm. The accuracy of the replica to master (the mean discrepancy) ranged from 0.5 to 2.0 μm (95% confidence interval 1.5-2.9 μm). Significance. The greatest precision of the measurement was seen in the jacket surface of the die. The size of the stone replicas varied and the repeatability coefficient was on average 15 μm (2-25 μm) greater for the replica-to-master alignment than the repeated digitizations of the master.
机译:目标。为了确定与主模型相比的数字化牙石复制品的可再现性以及计算机辅助分析的可靠性。方法。在预烧结的氧化钇稳定的四方氧化锆(Y-TZP)中制作了四个准备完整冠的母模。从每个模具中取出八个乙烯基聚硅氧烷印模(PROVIL novo; Heraeus Kulzer),并将石材复制品倒入IV型石材(Vel-Mix Stone; Kerr)中。在触摸探针扫描仪(Procera?Forte; Nobel Biocare AB)中将原模和石头复制品数字化,以创建三角表面模型。每个母模的第一次重复数字化中的点云都用作CAD参考模型(CRM)。三角曲面模型中的点与相应的CRM之间的差异通过匹配软件(CopyCAD 6.504 SP2; Delcam Plc)测量。分析差异的分布,并在色差图中显示。结果。测量方法的精度(以重复性系数表示)介于7和16(xm(整个表面)之间),而对石头复制品的分析表明,其精度(重复性系数)为19至26μm。复制品与母版(平均差异)范围为0.5到2.0μm(95%置信区间1.5-2.9μm)。意义。测量的最高精确度是在模具的外壳表面上看到的。副本到原版的对齐方式比原版的重复数字化平均重复性系数平均高15μm(2-25μm)。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号