首页> 外文期刊>Chromatographia >Simultaneous GC–MS Analysis of Melatonin and Its Precursors as Ethoxycarbonyl/Pentafluoropropionyl Derivatives in Rat Urine
【24h】

Simultaneous GC–MS Analysis of Melatonin and Its Precursors as Ethoxycarbonyl/Pentafluoropropionyl Derivatives in Rat Urine

机译:褪黑素及其前体作为大鼠尿液中的乙氧基羰基/五氟丙酰基衍生物的同时GC-MS分析

获取原文
获取原文并翻译 | 示例
           

摘要

Melatonin is synthesized from acetylserotonin, which is a deacetylated product of serotoinin. Simultaneous analysis of melatonin and its precursors in rat urine was performed using their (N,O)-ethoxycarbonyl/N-pentafluoropropionyl (EOC/PFP) derivatives by gas chromatography–mass spectrometry (GC–MS). The mass spectral data of acetylserotonin as mono-O-EOC/mono-N-PFP and serotonin as di-(N,O)-EOC/di-N-PFP derivatives were newly established. This method exhibited good linearity (r ≥ 0.996), repeatability (% relative standard deviation = 6.9–9.4), accuracy (% relative error = −8.9 to 8.6) with detection limits of 0.005 to 0.03 ng mL−1. This method was developed for the simultaneous measurement of melatonin and its precursors in rat urine.
机译:褪黑激素是由乙酰5-羟色胺合成的,乙酰5-羟色胺是血清素的去乙酰化产物。通过气相色谱-质谱法(GC-MS)使用它们的(N,O)-乙氧基羰基/ N-五氟丙酰基(EOC / PFP)衍生物对大鼠尿液中的褪黑素及其前体进行了同时分析。新建立了乙酰-5-羟色胺作为单-O-EOC /单-N-PFP和5-羟色胺作为二-(N,O)-EOC /二-N-PFP衍生物的质谱数据。该方法具有良好的线性(r≥0.996),可重复性(相对标准偏差%= 6.9–9.4),准确性(相对误差%= -8.9至8.6),检出限为0.005至0.03 ng mL -1 。开发了该方法用于同时测量大鼠尿液中的褪黑激素及其前体。