Time-frequency single-phase power components measurements for harmonics and inter-harmonics distortion based on Wavelet Packet transform;Part I: Mathematical formulation

机译:基于小波包变换的时频单相功率分量谐波和间谐波失真测量;第一部分:数学公式

获取原文
获取原文并翻译 | 示例
           

摘要

This paper represents the first part of a two-part study focusing on power components measurement in the time-frequency domain using Wavelet Packet Transform (WPT). The recommended power components that are contained in the IEEE Standard 1459-2010 [1] are derived based on the Fourier transform approach, which produces inaccurate results in the case of interharmonic distortion. On the other hand, the 'in-phase quadrature' approach that is defined in the time-domain can provide accurate values only for the total active power, total non-active power and total apparent power, while the remaining power components in this standard cannot be evaluated using this approach. This paper proposes redefining the recommended power components in [1] using the 'in-phase quadrature' approach in the time-frequency domain using WPT. This allows the evaluation of the all the recommended power components in both time and frequency domains while providing more accurate results than Fourier transform based approach, especially in case of inter-harmonic distortion. Moreover, defining those power components in the time-frequency domain provides a complete time-frequency picture for these components. This can be useful for many power system applications such as real-time monitoring of active and residual currents at each frequency, selective switching of harmonic, inter-harmonic elimination, instantaneous non-active power compensation and power quality evaluation.
机译:本文代表了由两部分组成的研究的第一部分,该研究集中于使用小波包变换(WPT)在时频域中测量功率分量。 IEEE标准1459-2010 [1]中包含的推荐功率分量是基于傅立叶变换方法得出的,该方法在间谐波失真的情况下会产生不准确的结果。另一方面,在时域中定义的“同相正交”方法只能提供总有功功率,总无功功率和总视在功率的准确值,而该标准中的其余功率分量无法使用这种方法进行评估。本文提出使用WPT在时频域中使用“同相正交”方法在[1]中重新定义推荐的功率分量。与基于傅立叶变换的方法相比,这可以评估时域和频域中所有推荐的功率分量,同时提供更准确的结果,尤其是在谐波间失真的情况下。此外,在时频域中定义那些功率分量可为这些分量提供完整的时频图。这对于许多电力系统应用很有用,例如实时监控每个频率下的有功和剩余电流,选择性切换谐波,消除谐波之间的干扰,瞬时无功功率补偿和电能质量评估。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号