Historically, wire markers were attached to cemented all-plastic acetabular cups to demarcate the periphery and to measure socket wear. The wire shape was either a semi-circle passing over the pole of the cup, or a circle around the cup equator. More recently, “double-D” shaped markers were introduced with a part-circular aspect passing over the pole and a semi-circular aspect parallel to the equatorial plane. This configuration enabled cup retroversion to be distinguished from anteversion. In this study, the accuracy of radiographic measurement of cup orientation and wear was assessed for cups with “double-D” and circular markers.Each cup was attached to a measurement jig which could vary the anteversion/retroversion and internal/ external rotation of the cup. A metal femoral head was fixed within the socket and radiographic images were created for all combinations of cup orientation settings. The images were measured using software with automatic edge detection, and cup orientation and zero-wear accuracies were determined for each setting.The median error for cup version measurements was similar for both types of wire marker (0.2° double-D marker, −0.24° circular marker), but measurements of the circular marker were more repeatable. The median inclination errors were 2.05° (double-D marker) and 0.23° (circular marker). The median overall “zero wear” errors were 0.19 mm (double-D marker) and 0.03 mm (circular marker). Measurements of the circular wire marker were much more repeatable.
机译:从历史上看,电线标记器被固定在全塑髋臼杯上,以划定边缘并测量承窝的磨损。线的形状可以是穿过杯子极点的半圆,也可以是围绕杯子赤道的圆。最近,引入了“双D”形标记,其部分圆形的部分越过极点,而半圆形的部分平行于赤道平面。这种配置使杯后退与前移有所区别。在这项研究中,对带有“双D”标记和圆形标记的杯子的射线照相测量杯定位和磨损的准确性进行了评估。每个杯都连接到一个测量夹具上,该夹具可以改变其前倾/内倾以及内外旋转。杯子。将金属股骨头固定在承窝内,并为杯定位设置的所有组合创建了放射线图像。使用具有自动边缘检测功能的软件对图像进行测量,并确定每种设置的杯子方向和零磨损精度。两种类型的金属丝标记器(0.2°double-D标记器,-0.24 °圆形标记),但圆形标记的测量更具可重复性。中位倾斜误差为2.05°(双D标记)和0.23°(圆形标记)。中位总体“零磨损”误差为0.19毫米(双D标记)和0.03毫米(圆形标记)。圆形线标记的测量具有更高的可重复性。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号