首页> 美国卫生研究院文献>Hand (New York N.Y.) >Report of a Transligamentous Ulnar Nerve SensoryBranch
【2h】

Report of a Transligamentous Ulnar Nerve SensoryBranch

机译:翻译ulnar神经感官的报告分支

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

Background: Several anatomical variations of the median nerverecurrent motor branch have been described. No previous reports have describedthe anatomical variation of the ulnar nerve with respect to transverse carpalligament. In this article, we present a patient with symptomatic compression ofthe ulnar nerve found to occur outside the Guyon canal due to a transligamentouscourse through the distal transverse carpal ligament. Methods: A59-year-old, right-hand-dominant male patient presented with right hand pain,subjective weakness, and numbness in both the ulnar and the median nervedistributions. Electromyography revealed moderate demyelinating sensorimotormedian neuropathy at the wrist and distal ulnar sensory neuropathy. At the timeof planned carpal tunnel and Guyon canal release, a transligamentous ulnar nervesensory common branch to the fourth webspace was encountered and safelyreleased. Results: There were no surgical complications. Thepatient’s symptoms of numbness in the median and ulnar nerve distributionclinically improved at his first postoperative visit. Conclusions:We have identified a case of transligamentous ulnar nerve sensory branchencountered during carpal tunnel release. To our knowledge, this has not beenpreviously reported. While the incidence of this variant is unknown, handsurgeons should be aware of this anatomical variant as its location puts it atrisk of iatrogenic injury during open and endoscopic carpal tunnel release.
机译:背景:中位神经的几种解剖学变化已经描述了经常性电机分支。没有描述过的报告尺骨神经相对于横向腕骨的解剖变异韧带。在本文中,我们呈现出症状压缩的患者由于易碎的概念,发现尺神经发现发生在Guyon Canal之外课程通过远端横向腕韧带。方法:A59岁,右手主导的男性患者呈现出右手疼痛,主观弱点,尺骨和中位神经中的麻木分布。肌电缩影显示适度的脱髓鞘传感器手腕和远端尺骨感觉神经病变中位神经病变。当时计划的腕管和Guyon Canal释放,一个翻译尺骨神经遇到并安全地遇到了第四个网站空间的感官公共分支发布。结果:没有手术并发症。这患者在中位数和尺骨神经分布中麻木的症状在他第一次术后访问临床上改善。结论:我们鉴定了一个翻译尺神经感觉分支的情况在腕管释放期间遇到。为了我们的知识,这不是以前报道。虽然这种变体的发病率未知,但手外科医生应该了解这种解剖变体,因为它的位置将其放在开放式和内窥镜腕管释放期间度源损伤的风险。

著录项

  • 期刊名称 Hand (New York N.Y.)
  • 作者单位
  • 年(卷),期 2020(15),1
  • 年度 2020
  • 页码 NP11–NP13
  • 总页数 3
  • 原文格式 PDF
  • 正文语种
  • 中图分类
  • 关键词

    机译:压缩神经病理;尺神经;翻译;腕管;甲骨感官分支;

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号