Multidetector row computed tomography (MDCT) creates massive amounts of data, which can overload a picture archiving and communication system (PACS). To solve this problem, we designed a new data storage and image interpretation system in an existing PACS. Two MDCT image datasets, a thick- and a thin-section dataset, and a single-detector CT thick-section dataset were reconstructed. The thin-section dataset was archived in existing PACS disk space reserved for temporary storage, and the system overwrote the source data to preserve available disk space. The thick-section datasets were archived permanently. Multiplanar reformation (MPR) images were reconstructed from the stored thin-section datasets on the PACS workstation. In regular interpretations by eight radiologists during the same week, the volume of images and the times taken for interpretation of thick-section images with (246 CT examinations) or without (170 CT examinations) thin-section images were recorded, and the diagnostic usefulness of the thin-section images was evaluated. Thin-section datasets and MPR images were used in 79% and 18% of cases, respectively. The radiologists’ assessments of this system were useful, though the volume of images and times taken to archive, retrieve, and interpret thick-section images together with thin-section images were significantly greater than the times taken without thin-section images. The limitations were compensated for by the usefulness of thin-section images. This data storage and image interpretation system improves the storage and availability of the thin-section datasets of MDCT and can prevent overloading problems in an existing PACS for the moment.
机译:多探测器行计算机断层扫描(MDCT)会创建大量数据,这可能会使图片存档和通信系统(PACS)过载。为了解决这个问题,我们在现有的PACS中设计了一个新的数据存储和图像解释系统。重建了两个MDCT图像数据集,一个厚截面和薄截面数据集,以及一个单探测器CT厚截面数据集。薄片数据集已存储在为临时存储保留的现有PACS磁盘空间中,并且系统重写了源数据以保留可用磁盘空间。厚截面数据集已永久存档。从PACS工作站上存储的薄层数据集中重建多平面重整(MPR)图像。在同一周内由八名放射科医生进行定期解释,记录了具有(246个CT检查)或不具有(170个CT检查)薄切片图像的厚切片图像的图像量和解释时间,并具有诊断意义评估了薄片图像的大小。薄层数据集和MPR图像分别用于79%和18%的病例。放射科医生对该系统的评估非常有用,尽管与不使用薄层图像的时间相比,将厚层图像与薄层图像一起进行存档,检索和解释所需的图像量和时间要大得多。薄层图像的有用性弥补了这些限制。该数据存储和图像解释系统改善了MDCT薄层数据集的存储和可用性,并且可以暂时防止现有PACS中的过载问题。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号