首页> 美国卫生研究院文献>other >Validation of x-ray fluorescence measurements of metals in toenail clippings against inductively coupled plasma mass spectrometry in a Nigerian population
【2h】

Validation of x-ray fluorescence measurements of metals in toenail clippings against inductively coupled plasma mass spectrometry in a Nigerian population

机译:尼日利亚人群中感应耦合等离子体质谱法对脚趾甲屑中金属的X射线荧光测量的验证

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

Metal exposures have been linked with many adverse health outcomes affecting nearly every system in the body. Exposure to metals has been tracked primarily using blood. Blood metal concentrations have drawbacks as biomarkers stemming from the metals’ short biologic half-lives, shipping and storage requirements, and invasive collection procedures. Toenails, which capture a longer exposure period, can be collected non-invasively and stored at room temperature, and can be more feasible and cost-effective for large-scale population studies. Inductively coupled plasma mass spectrometry (ICP-MS) has been used for analysis of toenail metal concentrations, but x-ray fluorescence (XRF) has many advantages in versatility and cost effectiveness over these analyses. This study compared toenail concentrations of manganese (Mn) and lead (Pb) measured with XRF against ICP-MS, in samples collected from 20 adults in Nigeria. To do this we developed a novel calibration method that corrects XRF measurements for toenail weight and thickness to reduce the variability in XRF measurements of toenail clippings. We found a high correlation (R=0.91) between toenail manganese metal measurements made with XRF and ICP-MS and a correlation of (R=0.32) between toenail lead XRF and ICP-MS with over half of the lead results below the detection limit of the instrumentation. XRF can be used effectively to quantify metals at the part per million level or lower depending on the XRF equipment used in the measurements.
机译:金属暴露已与影响身体几乎每个系统的许多不良健康后果相关。主要是使用血液来追踪金属的暴露。血中金属的浓度存在缺陷,因为生物标志物的来源是金属的半衰期短,运输和储存要求以及侵入性收集程序。脚趾甲可以捕获更长的暴露时间,可以无创地收集并在室温下保存,对于大规模人群研究而言,脚趾甲可能更可行且更具成本效益。电感耦合等离子体质谱法(ICP-MS)已用于分析脚趾甲金属浓度,但与这些分析相比,X射线荧光(XRF)在通用性和成本效益方面具有许多优势。这项研究比较了从尼日利亚20个成年人身上采集的XRF和ICP-MS测定的锰(Mn)和铅(Pb)的趾甲浓度。为此,我们开发了一种新颖的校准方法,该方法可校正趾甲重量和厚度的XRF测量值,以减少趾甲修剪的XRF测量值的可变性。我们发现用XRF和ICP-MS进行的趾甲锰金属测量之间的高度相关性(R = 0.91),并且趾甲铅XRF和ICP-MS之间的相关性(R = 0.32)与铅含量的一半以上低于检测限的仪器。根据测量中使用的XRF设备,XRF可以有效地用于百万分之一或更低的金属定量。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号