A frequency-based approach to locate common structure for 2D-3D intensity-based registration of setup images in prostate radiotherapy

机译:一种基于频率的方法来定位前列腺放射治疗中基于2D-3D强度的设置图像配准的通用结构

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

In many radiotherapy clinics, geometric uncertainties in the delivery of 3D conformal radiation therapy and intensity modulated radiation therapy of the prostate are reduced by aligning the patient's bony anatomy in the planning 3D CT to corresponding bony anatomy in 2D portal images acquired before every treatment fraction. In this paper, we seek to determine if there is a frequency band within the portal images and the digitally reconstructed radiographs (DRRs) of the planning CT in which bony anatomy predominates over non-bony anatomy such that portal images and DRRs can be suitably filtered to achieve high registration accuracy in an automated 2D-3D single portal intensity-based registration framework. Two similarity measures, mutual information and the Pearson correlation coefficient were tested on carefully collected gold-standard data consisting of a kilovoltage cone-beam CT (CBCT) and megavoltage portal images in the anterior-posterior (AP) view of an anthropomorphic phantom acquired under clinical conditions at known poses, and on patient data. It was found that filtering the portal images and DRRs during the registration considerably improved registration performance. Without filtering, the registration did not always converge while with filtering it always converged to an accurate solution. For the pose-determination experiments conducted on the anthropomorphic phantom with the correlation coefficient, the mean (and standard deviation) of the absolute errors in recovering each of the six transformation parameters were θx:0.18(0.19)°, θy:0.04(0.04)°, θz:0.04(0.02)°, tx:0.14(0.15) mm, ty:0.09(0.05) mm, and tz: 0.49(0.40) mm. The mutual information-based registration with filtered images also resulted in similarly small errors. For the patient data, visual inspection of the superimposed registered images showed that they were correctly aligned in all instances. The results presented in this paper suggest that robust and accurate registration can be achieved with intensity-based methods by focusing on rigid bony structures in the images while diminishing the influence of artifacts with similar frequencies as soft tissue.
机译:在许多放射治疗诊所中,通过将计划3D CT中的患者骨解剖与每个治疗分数之前获取的2D门脉图像中的相应骨解剖对齐,可以减少3D保形放射治疗和前列腺强度调制放射治疗的几何不确定性。在本文中,我们试图确定门CT图像和规划CT的数字重建射线照片(DRR)中是否存在频带,在这些图像中,骨解剖优于非骨解剖,因此可以适当过滤门图像和DRR在自动化的2D-3D基于单一门户强度的注册框架中实现高注册精度。在精心收集的黄金标准数据上测试了两个相似性度量,互信息和Pearson相关系数,这些数据由千伏锥束CT(CBCT)和兆伏门户图像在按以下方式获得的拟人幻影的前后(AP)视图中组成已知姿势和患者数据的临床状况。发现在注册过程中过滤门户网站图像和DRR大大提高了注册性能。如果没有过滤,则注册并不会总是收敛,而通过过滤,它总是会收敛为准确的解决方案。对于具有相关系数的拟人模型的姿势确定实验,在恢复六个变换参数中的每一个时,绝对误差的平均值(和标准差)为θx:0.18(0.19)°,θy:0.04(0.04) °,θz:0.04(0.02)°,tx:0.14(0.15)mm,ty:0.09(0.05)mm和tz:0.49(0.40)mm。基于相互信息的配准图像与过滤图像的配准也导致类似的小错误。对于患者数据,对叠加的注册图像进行目视检查表明它们在所有情况下均正确对齐。本文提出的结果表明,通过关注图像中的刚性骨结构,同时减少具有与软组织相似的频率的伪影的影响,可以使用基于强度的方法实现鲁棒且准确的配准。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号