摘要

BACKGROUND--Incremental threshold loading (ITL) is a test of inspiratory muscle performance which is usually performed by breathing through a weighted inspiratory plunger, the load on the inspiratory muscles being increased by externally adding weights to the intake valve. This is not a true threshold device and may be inaccurate. This method was compared with a true threshold device consisting of a solenoid valve which only opens to supply air at a predetermined negative mouth pressure. METHODS--Six naive, normal subjects (three men and three women) aged 22-24 years underwent three tests using each system. The inspiratory loads were increased every minute by equivalent amounts, -10 cm H2O with the solenoid valve and by 50 g with the weighted plunger, until the subjects could not inspire or sustain inspiration for a full minute. Six experienced subjects (four men and two women) aged 23-41 years were subsequently randomised to perform ITL with the solenoid valve, twice with the breathing pattern fixed and twice free. RESULTS--The solenoid valve generated a more accurate mouth pressure response and was less variable at higher loads than the weighted plunger. The work performed (expressed as the pressure-time product) was less with the solenoid valve but was more reproducible. ITL with the solenoid valve was not influenced by controlling the breathing pattern of the subjects. CONCLUSIONS--The solenoid valve has several features that make it superior to the weighted plunger as a device for ITL. It generates a more accurate mouth pressure response which is less variable at higher loads. Increases in load are smoother and quicker to introduce. ITL with the solenoid valve is not influenced by varying breathing patterns and does not require any external regulation.
机译:背景技术-增量阈值负荷(ITL)是对吸气肌肉性能的测试,通常是通过加权吸气柱塞进行呼吸来进行的,通过在外部增加进气门的重量来增加吸气肌肉的负载。这不是真正的阈值设备,可能不准确。将该方法与由电磁阀组成的真正阈值设备进行了比较,该电磁阀仅打开以预定的负压向空气供应。方法-六名22-24岁的天真的,正常的受试者(三名男性和三名女性)接受了每种系统的三项测试。吸气负荷每分钟增加等效量,使用电磁阀增加-10 cm H2O,并使用加重柱塞增加50 g,直到受试者无法在一整分钟内激发或维持吸气。随后将六名年龄在23-41岁之间的有经验的受试者(四名男性和两名女性)随机分配到使用电磁阀执行ITL,两次固定呼吸模式,两次自由呼吸。结果-电磁阀产生的口压力响应更准确,并且在较高负载下的可变性比称重柱塞小。电磁阀执行的功(表示为压力时间乘积)较少,但可重复性更高。电磁阀的ITL不受控制受试者的呼吸方式的影响。结论-电磁阀具有多项功能,使其优于配重柱塞作为ITL的设备。它产生更精确的嘴压力响应,在较高负载下变化较小。负载的增加更平稳,更快地引入。带有电磁阀的ITL不受呼吸模式变化的影响,并且不需要任何外部调节。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号