首页> 美国卫生研究院文献>Experimental and Therapeutic Medicine >Evaluation of blunt pancreatic injury with contrast-enhanced ultrasonography in comparison with contrast-enhanced computed tomography
【2h】

Evaluation of blunt pancreatic injury with contrast-enhanced ultrasonography in comparison with contrast-enhanced computed tomography

机译:超声造影与对比计算机断层扫描对比评价钝性胰腺损伤

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

The aim of the present study was to evaluate acute blunt pancreatic injury using contrast-enhanced ultrasonography (CEUS) in comparison with contrast-enhanced computed tomography (CECT). Superficial and deep lesions were established by blunt pancreatic injury in 40 Chinese Guangxi Bama miniature pigs. Conventional ultrasound (US), CEUS and CECT were performed to detect traumatic lesions in the pancreas. A total of 40 lesions were established, including 20 deep lesions and 20 superficial lesions. US identified 21 of the 40 lesions, including 7 of the 20 superficial and 14 of the 20 deep lesions. CEUS identified 34 of the 40 lesions, including 14 of the 20 superficial and 20 of the 20 deep lesions. CECT identified 33 of the 40 lesions, including 13 of the 20 superficial and 20 of the 20 deep lesions. The detection rate of acute blunt pancreatic injury using CEUS was significantly higher compared with that using US (85 vs. 52.5%, P<0.05), however there was no significant difference in the detection rate of pancreatic lesions between CEUS and CECT (85 vs. 82.5%, P>0.05). CEUS improves the diagnostic levels of conventional US and is comparable with CECT scans in the diagnosis of blunt pancreatic injury.
机译:本研究的目的是与对比增强型计算机体层摄影术(CECT)相比,使用对比增强型超声检查(CEUS)评估急性钝性胰腺损伤。通过钝性胰腺损伤在40只广西巴马小型猪中建立了浅表和深部病变。进行常规超声(US),CEUS和CECT来检测胰腺的创伤性病变。共建立了40个病变,包括20个深层病变和20个浅表病变。 US确定了40个病变中的21个,包括20个浅表病变中的7个和20个深部病变中的14个。 CEUS确定了40个病变中的34个,包括20个浅表病变中的14个和20个深部病变中的20个。 CECT确定了40个病变中的33个,包括20个浅表病变中的13个和20个深部病变中的20个。与US相比,CEUS对急性钝性胰腺损伤的检出率明显高于美国(85 vs. 52.5%,P <0.05),但CEUS和CECT对胰腺病变的检出率无明显差异(85 vs. 82.5%,P> 0.05)。 CEUS可提高常规US的诊断水平,在钝性胰腺损伤的诊断中可与CECT扫描相媲美。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号