首页> 美国卫生研究院文献>Frontiers in Veterinary Science >Bias due to Preanalytical Dilution of Rodent Serum for Biochemical Analysis on the Siemens Dimension Xpand Plus
【2h】

Bias due to Preanalytical Dilution of Rodent Serum for Biochemical Analysis on the Siemens Dimension Xpand Plus

机译:西门子Dimension Xpand Plus对生化分析进行鼠齿血清分析前稀释导致的偏差

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

Clinical pathology testing of rodents is often challenging due to insufficient sample volume. One solution in clinical veterinary and exploratory research environments is dilution of samples prior to analysis. However, published information on the impact of preanalytical sample dilution on rodent biochemical data is incomplete. The objective of this study was to evaluate the effects of preanalytical sample dilution on biochemical analysis of mouse and rat serum samples utilizing the Siemens Dimension Xpand Plus. Rats were obtained from end of study research projects. Mice were obtained from sentinel testing programs. For both, whole blood was collected via terminal cardiocentesis into empty tubes and serum was harvested. Biochemical parameters were measured on fresh and thawed frozen samples run straight and at dilution factors 2–10. Dilutions were performed manually, utilizing either ultrapure water or enzyme diluent per manufacturer recommendations. All diluted samples were generated directly from the undiluted sample. Preanalytical dilution caused clinically unacceptable bias in most analytes at dilution factors four and above. Dilution-induced bias in total calcium, creatinine, total bilirubin, and uric acid was considered unacceptable with any degree of dilution, based on the more conservative of two definitions of acceptability. Dilution often caused electrolyte values to fall below assay range precluding evaluation of bias. Dilution-induced bias occurred in most biochemical parameters to varying degrees and may render dilution unacceptable in the exploratory research and clinical veterinary environments. Additionally, differences between results obtained at different dilution factors may confound statistical comparisons in research settings. Comparison of data obtained at a single dilution factor is highly recommended.
机译:由于样本量不足,啮齿动物的临床病理学测试通常具有挑战性。临床兽医和探索性研究环境中的一种解决方案是在分析之前稀释样品。但是,有关分析前样品稀释对啮齿动物生化数据影响的公开信息并不完整。这项研究的目的是评估使用Siemens Dimension Xpand Plus对样品进行分析前稀释对小鼠和大鼠血清样品的生化分析的影响。从研究结束时获得大鼠。从前哨测试程序获得小鼠。两者均通过终末心脏穿刺术将全血收集到空管中,并收集血清。生化参数是在新鲜和解冻的冷冻样品中直接测量的,稀释倍数为2-10。根据制造商的建议,使用超纯水或酶稀释剂手动进行稀释。所有稀释的样品均直接从未稀释的样品中生成。在稀释系数为4或更高时,分析前稀释在大多数分析物中引起临床上不可接受的偏差。基于可接受性的两个定义中的较保守性,在任何稀释度下,总钙,肌酐,总胆红素和尿酸的稀释引起的偏差均被认为是不可接受的。稀释通常会导致电解质值降至测定范围以下,从而无法评估偏差。稀释引起的偏差在大多数生化参数中都不同程度地发生,并且可能使稀释性在探索性研究和临床兽医环境中不可接受。此外,在不同稀释因子下获得的结果之间的差异可能会混淆研究环境中的统计比较。强烈建议比较单个稀释因子下获得的数据。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号