首页> 中文期刊> 《分析化学》 >电化学发光-分子印迹传感器的制备及其在海洛因检测中的应用

电化学发光-分子印迹传感器的制备及其在海洛因检测中的应用

         

摘要

利用掺杂多壁碳纳米管( MWNTs)的 Nafion 膜在玻碳电极上固定联吡啶钌( Ru(bpy)2+3),制得 Ru(bpy)2+3/ Nafion/ MWCNT 修饰电极。为了提高修饰电极的选择性,通过溶胶-凝胶技术,对该电极进一步修饰了溶胶-凝胶分子印迹膜,制得电化学发光-分子印迹传感器。优化了扫速、pH 值、富集时间等检测条件,传感器显示出既具电化学发光技术的灵敏性和分子印迹技术的选择性。在优化条件下,即 pH 7.0的磷酸盐缓冲溶液中,以100 mV/ s 扫速,富集5 min,对海洛因进行检测,在1.0×10-10~1.0×10-14 mol/ L 范围内有良好线性关系,检出限可达到4.0×10-15 mol/ L(S/ N=3)。传感器直接应用于唾液和尿液中海洛因的测定,回收率达到97%~104%。%An electrochemiluminescence (ECL) sensor with molecularly imprinted polymer (MIP) film was prepared for the determination of heroin. The sensor was prepared by re-modifying the molecular imprinting membrane onto the Ru ( bpy ) 2+3 modified glassy carbon electrode. The electrochemical and electrochemiluminescence behavior of the sensor was investigated. The proposed sensor displayed high sensitivity and excellent selectivity for the target molecule heroin. Under the optimum conditions (0. 1 mol/ L PBS (pH 7. 0) at a scan rates of 100 mV/ s and incubation time of 5 min), a linear response was observed with the concentrations of heroin from 1. 0 × 10-14 mol/ L to 1. 0 ×10-10 mol/ L and the detection limit was 4. 0 × 10-15 mol/ L. The sensor was successfully applied to the determination of heroin in urineand saliva samples with the recoveries from 97% to 104% .

著录项

  • 来源
    《分析化学》 |2014年第6期|904-908|共5页
  • 作者

    商哲一; 韩超峰; 宋启军;

  • 作者单位

    教育部食品胶体与生物技术重点实验室;

    江南大学化学与材料工程学院;

    无锡 214122;

    教育部食品胶体与生物技术重点实验室;

    江南大学化学与材料工程学院;

    无锡 214122;

    教育部食品胶体与生物技术重点实验室;

    江南大学化学与材料工程学院;

    无锡 214122;

  • 原文格式 PDF
  • 正文语种 chi
  • 中图分类
  • 关键词

    海洛因; 电化学发光; 分子印迹; 溶胶-凝胶; 传感器;

相似文献

  • 中文文献
  • 外文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号