首页> 外文会议>ASME summer bioengineering conference;SBC2010 >Test to Fracture of Cardiac Lead Coils in Unidirectional Bending Fatigue
【24h】

Test to Fracture of Cardiac Lead Coils in Unidirectional Bending Fatigue

机译:单向弯曲疲劳中心脏导丝断裂的测试

获取原文
获取原文并翻译 | 示例

摘要

A new test method for generating in-vitro unidirectional bending fatigue fractures has been developed. The method has been used to measure the fatigue curvature-vs.-life relationship of four coils within four defibrillation lead designs. The results are consistent with conventional fatigue theory. The test method and curvature-based fatigue curves are well suited for use alongside existing techniques for measuring the in-vivo curvature change in leads. Future work is needed to expand the testing into high cycle fatigue realms, and to evaluate the sensitivity of fatigue performance to coil design parameters.
机译:开发了一种新的体外单向弯曲疲劳断裂试验方法。该方法已用于测量四个除颤导线设计中四个线圈的疲劳曲率与寿命的关系。结果与传统的疲劳理论是一致的。该测试方法和基于曲率的疲劳曲线非常适合与现有技术一起用于测量引线的体内曲率变化。需要做进一步的工作,以将测试扩展到高周疲劳领域,并评估疲劳性能对线圈设计参数的敏感性。