Wafer-level testing of surface-micromachined sensors provides new challenges to the test community. Currently, there is no method available for performing direct measurements to assess faulty micromechanical structures. Most commercial methods use electrical measurements to deduce the physical source of failures in the micromechanical structure. As a result, the process of identifying various failure modes (electrical measurements) and accurately mapping them to the underlying physical failure mechanisms of the mechanical sensor becomes highly complex. Several sources of failures that include particulates and stiction complicate the situation even more. Here, we provide a case study of the Analog Devices ADXL75 Accelerometer. One failure category called stuck/tipped beams is investigated and a methodology is developed to uniquely distinguish failures either caused by stuck or tipped beams. The proposed method is easy to implement and the information obtained can be critical for yield improvement.
机译:表面微磨传感器的晶圆级测试为测试界提供了新的挑战。目前,没有可用于执行直接测量以评估错误的微机械结构的方法。大多数商业方法使用电气测量来推导微机械结构中的故障物理源。结果,识别各种故障模式(电测量)并将其精确地将其映射到机械传感器的底层物理故障机制的过程变得非常复杂。包括颗粒物和睾丸的几种失败来源使情况更加复杂。在这里,我们提供了模拟设备ADXL75加速度计的案例研究。研究了一个名为卡住/尖梁梁的故障类别,并且开发了一种方法,以唯一地区分由卡住或尖梁引起的故障。所提出的方法易于实现,并且获得的信息对于产量改进至关重要。