首页> 外文会议>IEEE Industrial Electronics and Applications Conference >An Interleaved Boost Power Factor Corrector with Average Current Control for Off-Line Power Supplies
【24h】

An Interleaved Boost Power Factor Corrector with Average Current Control for Off-Line Power Supplies

机译:截线电流控制平均电流控制的交错升压功率因数校正

获取原文

摘要

An interleaved boost power-factor corrector (PFC) with average current control is studied in this paper. It comprises two interleaved boost circuits connected in parallel and operated with average current control. The interleaved operation reduces the input current and output current ripples and also improves the circuit efficiency at light load condition. This paper analyzes the interleaved PFC pre-regulator and implements a 1.2kW prototype with a ready-made commercial integrated circuit UCC28070. Experimental results demonstrate the analysis and design of this paper.
机译:本文研究了具有平均电流控制的交错升压功率因数校正器(PFC)。它包括并联连接的两个交错升压电路,并且使用平均电流控制操作。交织操作降低了输入电流和输出电流纹波,并且还可以在轻负载条件下提高电路效率。本文分析了交错PFC预调节器,并用现成的商业集成电路UCC28070实现1.2KW原型。实验结果表明了本文的分析和设计。

著录项