This paper analyzes laminar and turbulent flow velocity in detail based on the knowledge of fluid dynamics. With this theoretical base, this paper then deduces calibration coefficient formula of ultrasonic flow meter, and designs calibration method to meet the actual fluid state. And finally, uses the iterative method to make it with the single-channel DN100 ultrasonic flow meter. The analysis of the experimental dada indicates that the calibration method has greatly improved the two important indicators: the accuracy and repeatability of ultrasonic flow meter.
机译:本文基于流体动力学的知识,详细分析了层流和湍流速度。 本文采用了本文,然后推出超声波流量计的校准系数配方,并设计校准方法以满足实际的流体状态。 最后,使用迭代方法使其与单通道DN100超声波流量计进行。 实验DADA的分析表明,校准方法大大提高了两个重要指标:超声波流量计的准确性和可重复性。