首页> 外文会议>International Conference on Applied Sciences, Engineering and Technology >Determination of Rhodium in Waste Rhodium-loaded Carbon Catalyst Samples using Teflon Pressure Vessel-assisted Sample Digestion and ICP-AES
【24h】

Determination of Rhodium in Waste Rhodium-loaded Carbon Catalyst Samples using Teflon Pressure Vessel-assisted Sample Digestion and ICP-AES

机译:用Teflon压力容器辅助样品消化和ICP-AES测定废铑负载碳催化剂样品中铑的测定

获取原文

摘要

A novel method for the determination of rhodium in waste rhodium-loaded carbon catalyst samples was established by inductively coupled plasma atomic emission spectrometry after samples digested by Teflon pressure digestion vessel with aqua regia. Such experiment conditions were investigated as the influence of sample dissolution methods, digestion time, digestion temperature and interfering ions on the determination. The results indicated that the digestion effect was optimum with samples digested 8 hour at 180 °C. Al, Fe, Mg, Ca and Si in samples had no effect on the determination of rhodium. Experiment indicated rhodium concentration within the range of 0 ~ 150 mg L"1 had a linear relation with emission intensity. The recovery was 99.20% ~ 100.73%, and the relative standard deviation was 1.8%. A satisfactory result was obtained when applying the proposed method in the practical sample.
机译:用Aqua Regia消化的样品在用浅料消化血管消化后的样品后,通过电感偶联等离子体原子发射光谱法确定了一种新的用于测定废铑碳催化剂样品中的铑。研究了这种实验条件作为样品溶解方法,消化时间,消化温度和干扰离子对测定的影响。结果表明消化效果最佳,样品在180℃下消化了8小时。样品中的Al,Fe,Mg,Ca和Si对铑的测定没有影响。实验表明,0〜150mg L“1的铑浓度具有与发射强度的线性关系。回收率为99.20%〜100.73%,相对标准偏差为1.8%。申请建议时获得令人满意的结果实际样品中的方法。