Contemporary drug eluting stents (DES) are designed and tested such that they will endure under in vivo fatigue loading after implantation. However, DES fractures have occasionally been reported in the literature and are often associated with restenosis and/or thrombosis events long after DES deployment. This observation indicates a need for fatigue test methods which appropriately compare the fatigue resistance of various DES platforms at loading levels beyond clinical relevance. The setup of this type of fatigue test involves applying repetitive displacement-overload or force-overload conditions to compare fatigue resistance under aggressive yet clinically meaningful loading. In the present work, these two overloading philosophies are compared using finite element analysis (FEA) with the aim of selecting a loading approach that is capable of appropriately evaluating the bending fatigue resistance of stent platforms with varying stiffness attributes.
机译:当代药物洗脱支架(DES)设计和测试,使得它们将在植入后体内疲劳负载恢复。然而,在文献中偶尔报道了DES裂缝,并且通常与DES部署后长期与再狭窄和/或血栓形成事件相关联。该观察结果表明需要疲劳试验方法,该试验方法适当地比较临床相关性超越临床相关性的各种DES平台的疲劳性。这种类型的疲劳试验的设置涉及应用重复的位移 - 过载或力过载条件,以比较侵略性且临床上有意义的负载下的疲劳抵抗力。在本作本作中,使用有限元分析(FEA)比较这两个重载哲学,目的是选择能够适当地评估具有不同刚度属性支架平台的弯曲疲劳电阻的加载方法。