AUTONOMOUS MONITORING UNIT, SIGNS AND REGISTRATION FOR COBALT-60 IRRADIATOR SAFETY SYSTEM

机译:自主监控单元,钴-60辐照器安全系统的标志和注册

获取原文

摘要

The Cobalt-60 irradiator of IPEN/CNEN, a category IV facility, has a security system for inter locking doors or exposure of radioactive sources made simultaneously by a programmable logic controller (PLC) model S7-200 from Siemens and a relay logic. From a set of information, the both systems work together opening doors or exposing the sources. All incoming and outgoing information are sent serially via EIA232 communication to a personal computer with Windows platform for a supervisory program which provides besides a monitoring the entire process by a synoptic table on the computer screen, also keeps records of all events on the computer's hard drive. The electronic management has proven to be efficient and has not produced any failure that had compromised the safety. The PLC along with the relay logic has always taken the right decisions ensuring proper radiation protection of operators and the integrity of radioactive sources, but it presented over the years of operation (beginning in 2004) less than a dozen flaws in system event log. The deficiency was found between the process of sending events via serial communication (EIA232) to the supervisory program. When failure occurs in a very short time, the PLC always took the right decision, but the registration process that had to go through the Windows timeshare lost the information. This work aimed to build a standalone electronics connect the inputs and outputs of the security system, fully optocoupled to avoid any interference to the security system. It records each event on a memory card, waits for the right decision of the security system and in case of an incorrect decision an independent alarm notifies its own synoptic picture, and sends a text message to a group of defined cellphones. The circuit uses two microcontrollers called "main" and "secondary". The main is responsible for the control and monitoring of peripheral inputs and outputs of the security system. The main is monitored by the secondary, thus creating a redundant. Again, if a wrong operation is detected an auxiliary alarm is triggered.
机译:IPEN / CNEN的钴-60辐照器,IV类别设施,具有来自西门子和中继逻辑的可编程逻辑控制器(PLC)S7-200同时锁定门或放射源曝光的安全系统。从一组信息,两个系统一起使用打开门或暴露源。所有传入和传出信息都通过EIA232通信发送到带有Windows平台的个人计算机,用于监督程序,除了计算机屏幕上的SYNOPTIC表的监控外,还可以在计算机硬盘上保留所有事件的记录。电子管理已被证明是高效的,并且没有产生任何损害安全性的故障。 PLC以及继电器逻辑一直采取正确的决策,确保操作员的适当辐射保护以及放射源的完整性,但它在多年的操作中(从2004年开始)少于系统事件日志的十几个缺陷。通过串行通信(EIA232)向监督计划发送事件的过程之间存在缺陷。当在很短的时间内发生故障时,PLC始终采取正确的决定,但必须通过Windows TimeShare的注册过程失去了信息。这项工作旨在构建独立电子设备,可以完全选择安全系统的输入和输出,以避免对安全系统的任何干扰。它将每个事件记录在存储卡上,等待安全系统的正确决定,如果确定的决定不正确,则独立警报通知其自己的概觉图片,并将文本消息发送到一组定义的蜂窝电话。该电路使用称为“主”和“次级”的两个微控制器。主要负责控制和监控安全系统的外围输入和输出。主要由次级监控主,从而创建冗余。同样,如果检测到错误的操作,则触发辅助警报。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号