首页> 外文会议>International Conference on New Energy and Sustainable Development >Optimization Study of Ground-Source Heat Pump Heating Systems in Extremely Cold Areas
【24h】

Optimization Study of Ground-Source Heat Pump Heating Systems in Extremely Cold Areas

机译:极冷地区地下源热泵加热系统的优化研究

获取原文

摘要

Optimization study of ground-source heat pump heating systems is significant in extremely cold areas. Through the ground-source heat pump system built in extremely cold areas, the optimization of the heating conditions of system is researched. The results show that the average COP value of the system is increased by 9.8% when the system is intermittent in operations and the average COP of system is increased by 11.1% when two compressors operate and the circulating pumps adopt the inverter control. The average COP of the heat pump is increased by 4.3% when 3 compressors operate and the circulating pumps adopt the inverter control. This shows that the system optimization is very necessary with the ground-source heat pump system in severe cold regions, and can further improve the efficiency of system.
机译:地面源热泵加热系统的优化研究在极冷的区域中显着。通过内置极冷地区的地源热泵系统,研究了系统的加热条件的优化。结果表明,当系统在操作中间歇性时,系统的平均COP值增加了9.8%,当两个压缩机操作和循环泵采用逆变器控制时,系统的平均COP增加11.1%。当3压缩机操作和循环泵采用逆变器控制时,热泵的平均COP增加了4.3%。这表明系统优化在严重的寒冷地区的地源热泵系统中是非常必要的,并且可以进一步提高系统的效率。