首页> 外文会议>International Seminar on Fundamental and Application of Chemical Engineering >Application of Dual Membrane Contactor for Simultaneous CO_2 Removal Using Continues Diethanolamine (DEA)
【24h】

Application of Dual Membrane Contactor for Simultaneous CO_2 Removal Using Continues Diethanolamine (DEA)

机译:双膜接触器用于同时CO_2去除使用延续二乙醇胺(DEA)

获取原文

摘要

Technology of membrane contactor is an improvemet of acid gas (CO_2) removal technology that combining gas absorption process with solvent and membrane technology. The objective of the experiment are study the effect of feed gas flow rate and solvent to flux CO_2 and efficiency of CO_2 removal, and also study the performance of membrane contactor. The experiment is conducted by circulating DEA in certain flow rate and arranging hollow fiber membrane in double-crossed section with the amount of desorption membrane three times more than absorption membrane. Feed gas streamed in the tube of membrane absorption and solvent on the shell. At the same time and condition, the process of desorption is done by streamed N_2 gas as the stripping gas in desorption membrane. Performance test is conducted by running optimum variable for 8 hours. The result showed that flux of absorption gain the highest at 24,747xl0~(-4) mol/m~2.s, while flux of desorption gain the highest at 1,761 x 10~(-4) mol/m~2.s. Increasing of absorption flux correspond to increasing of flow rate of feed gas and CO_2 gas concentration but decreasing in flow rate of solvent. Increasing of desorption flux correspond to increasing of flow rate of feed gas and solvent but concentration of CO_2 does not have impact. Efficiency increase while flow rate of mix gas and solvent decreasing, but CO_2 concentration increase. The highest efficiency is 61,64%. Efficiency performance for CO_2 removal of module membrane has the highest value at first 2 hours and stay constant at next running for 8 hours.
机译:膜接触器技术是酸性气体(CO_2)去除技术的改进,使气体吸收过程与溶剂和膜技术相结合。实验的目的是研究进料气体流速和溶剂对助焊剂CO_2的影响和CO_2去除效率,还研究膜接触器的性能。通过以某些流速循环DEA和将中空纤维膜布置在双交叉截面中的三倍,比吸收膜的量循环进行实验。进料气体在膜中膜吸收和溶剂上的溶剂。在同一时间和条件下,解吸过程通过流式的N_2气体作为解吸膜中的汽提气体来完成。通过运行8小时的最佳变量进行性能测试。结果表明,吸收焊剂在24,747×10〜(-4)摩尔/ m〜2中最高。磁通量在1,761×10〜(-4)Mol / m〜2中最高。吸收通量的增加对应于进料气体和CO_2气体浓度的流速的增加,但溶剂的流速降低。降解通量的增加对应于进料气体和溶剂的流速的增加,但浓度的CO_2没有撞击。效率增加,而混合气体的流速和溶剂的流速降低,但CO_2浓度增加。最高效率为61,64%。 CO_2的效率性能对模块膜的去除具有最高值在前2小时的最高值,并在下一次运行8小时后保持恒定。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号