摘要

Methyl valerate (C_6H_(12)O_2, methyl pentanoate) is a methyl ester and a relevant surrogate component for biodiesel. In this work, we present ignition delays of methyl valerate measured using a rapid compression machine at a range of engine-relevant temperature, pressure, and equivalence ratio conditions. The conditions we have studied include equivalence ratios from 0.25 to 2.0, temperatures between 680 K and 1050 K, and pressures of 15 bar and 30 bar. The ignition delay data demonstrate a negative temperature coefficient region in the temperature range of 720 K-800 K for both Φ = 2.0, 15 bar and Φ = 1.0, 30 bar, with two-stage ignition apparent over the narrower temperature ranges of 720 K-760 K for the lower pressure and 740 K-760 K at the higher pressure. In addition, the experimental ignition delay data are compared with simulations using an existing chemical kinetic model from the literature. The simulations with the literature model under-predict the data by factors between 2 and 10 over the entire range of the experimental data. To help determine the possible reasons for the discrepancy between simulations and experiments, a new chemical kinetic model is developed using the Reaction Mechanism Generator (RMG) software. The agreement between the experimental data and the RMG model is improved but still not satisfactory. Directions for future improvement of the methyl valerate model are discussed.
机译:甲基戊酯(C_6H_(12)O_2,甲基戊己酸酯)是甲酯和生物柴油的相关替代组分。在这项工作中,我们在发动机相关温度,压力和等效比率范围内使用快速压缩机测量的甲基戊符的点火延迟。我们研究的条件包括0.25至2.0的等效比,680 k和1050 k之间的温度,以及15巴的压力和30巴。点火延迟数据在φ= 2.0,15巴和φ= 1.0,30巴的720k-800k的温度范围内展示负温度系数区域,在720k的较窄温度范围内具有两阶段点火。 -760 k用于较低压力和740 k-760 k在较高压力下。此外,使用来自文献的现有化学动力学模型将实验点火延迟数据与模拟进行比较。与文献模型的模拟在实验数据的整个范围内通过2和10之间的因素预测数据。为了帮助确定模拟和实验之间差异的可能原因,使用反应机制发生器(RMG)软件开发了一种新的化学动力学模型。实验数据与RMG模型之间的协议得到改善,但仍然不令人满意。讨论了未来改善甲基戊符模型的方向。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号