Vertical Kaplan turbines, with nominal power of 178 MW and manufactured in Russia, have been installed in 6 hydroelectric generating units of hydro power plant 'Djerdap 1'. Experimental tests were carried out by non-destructive methods in order to determine the turbine condition during the rehabilitation of the hydro power plant. Lack of root penetration was detected in V40 welded joints between upper and lower sleeves and bodies of guide vane apparatus vanes. Height of the lack of root penetration was in the range between 5 and 15 mm, while the allowable height of the lack of root penetration is 3 mm, according to the technical conditions. The upper sleeves were made of cast steel 25L (in accordance with GOST 977), while lower sleeves were made of steel forging St 25 (in accordance with standards GOST 1050 for chemical composition and GOST 8479 for forgings). Methodology for the repair of non-penetrated welded joints between the sleeves and body of the guide vane apparatus vane was composed taking into account the results of ultrasonic testing. By repair methodology it is necessary to, due to the structural solution and service function of guide vane apparatus vanes, specify a large number of details, consider them carefully and carry them out in order to improve safety, because if some of them get overlooked, underestimated or incorrectly perceived, significant problems in turbine operation may occur. This methodology refers solely to the repair of damaged welded joints between sleeves and bodies of guide vane apparatus vanes.
机译:垂直Kaplan涡轮机,标称功率为178兆瓦,在俄罗斯制造,已安装在6个水流发电机厂'Djerdap 1'的水力发电单元中。通过非破坏性方法进行实验测试,以确定水电站康复过程中的涡轮机状态。在V40焊接接头中检测到缺乏根渗透,在上下套筒和导向叶片设备叶片的上下套筒和底部。根据技术条件,缺乏根渗透的高度在5和15毫米之间的范围内,缺乏根渗透的允许高度为3毫米。上套管由铸钢25L制成(根据GOST 977),而下套管由钢锻造ST 25制成(根据化学成分的标准1050,用于锻件的GOST 8479)。考虑到超声波测试的结果,构成了引导叶片设备叶片的套管和主体之间的非穿透焊接接头的修复方法。通过修复方法,由于导向叶片设备叶片的结构解决方案和服务功能,指定大量细节,仔细考虑它们并将它们携带以便提高安全性,因为如果其中一些人被忽视,因此低估或错误地感知,可能发生涡轮机操作中的重大问题。该方法仅指在导向叶片设备叶片的套管和砂体之间的损坏焊接接头的修复。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号