首页> 外文会议>International Conference on Concentrating Solar Power and Chemical Energy Systems >Parabolic Trough Receiver Heat Loss and Optical Efficiency Round Robin 2015/2016
【24h】

Parabolic Trough Receiver Heat Loss and Optical Efficiency Round Robin 2015/2016

机译:抛物面槽接收器热量损失和光学效率循环2015/2016

获取原文

摘要

A round robin for parabolic trough receiver heat loss and optical efficiency in the laboratory was performed between five institutions using five receivers in 2015/2016. Heat loss testing was performed at three cartridge heater test benches and one Joule heating test bench in the temperature range between 100 °C and 550 °C. Optical efficiency testing was performed with two spectrometric test bench and one calorimetric test bench. Heat loss testing results showed standard deviations at the order of 6% to 12 % for most temperatures and receivers and a standard deviation of 17 % for one receiver at 100 °C. Optical efficiency is presented normalized for laboratories showing standard deviations of 0.3 % to 1.3 % depending on the receiver.
机译:在2015/2016年使用五个接收器在五个机构之间使用五个机构在实验室中进行抛物线槽热损失和光学效率的循环罗宾。在三个盒式加热器试验台和100°C至550°C之间的温度范围内进行热量损失测试。使用两个光谱测试台和一个量热测试台进行光学效率测试。热量损失测试结果显示,大多数温度和接收器的标准偏差为6%至12%,一个接收器在100°C时为17%的标准偏差。提出了光学效率,用于实验室,显示标准偏差,根据接收器,标准偏差为0.3%至1.3%。