The flow rate meter based on the Laser Doppler Anemometer (LDA) has been developed to evaluate the fuel injection rate. The flow rate meter is called as LDA flow rate meter. The instantaneous flow rate has been measured at the upstream of an injector. The measured results of instantaneous flow rate are influenced by reflection pressure waves from the end of pipe. The effects of the pressure waves appear as undesirable oscillations in the results of the instantaneous flow rate. A reducing method of the oscillations is proposed as data correction. Corrected data of LDA flow rate meter have similar profiles to the results by the BOSCH-Type injection indicator. The results indicate the instantaneous injection rate can be evaluated by using the LDA flow rate meter.
机译:已经开发出基于激光多普勒风速计(LDA)的流量计来评估燃料喷射率。流量计称为LDA流量计。在喷射器的上游测量了瞬时流速。瞬时流速的测量结果受管子末端的反射压力波的影响。压力波的效果在瞬时流速的结果中看起来是不希望的振荡。提出了振荡的还原方法作为数据校正。 LDA流量表的校正数据对博世型注射指示器的结果具有类似的简档。结果表明可以通过使用LDA流速表来评估瞬时注射率。