首页> 外文会议>RMUTP International Conference on Science, Technology and Innovation for Sustainable Development >Determination of Total Arsenic Using Microwave Digestion Technique-Graphite Furnace Atomic Absorption Spectrophotometry
【24h】

Determination of Total Arsenic Using Microwave Digestion Technique-Graphite Furnace Atomic Absorption Spectrophotometry

机译:使用微波消解技术 - 石墨炉原子吸收分光光度法测定总砷

获取原文

摘要

The aim of this work was to validate the sample preparation using a microwave digestion for determination of total arsenic in a spiked soil. Graphite furnace atomic absorption spectrophotometer (GFAAS) technique was used to determine the total arsenic using palladium nitrate as a modifier agent. The instrumental detection was performed under the condition steps of drying, ashing, atomizing and cleaning to be 100, 1200, 2250 and 2600°C, respectively. The external calibration curve was constructed using the automatic program with the master standard of 20 ppb arsenic solution. It was found that linearity range was in the range of 1 to 20 ppb with R~2>0. 999. The LOD and LOQ were 0.10 and 1.0 ppb, respectively. Based on two microwave digestion programs, the total arsenic obtained from the preparation method with HF and without HF were also compared. The result showed that the arsenic content obtained from both methods did not significantly different at the 95% confidence limit. The percentage of recovery was 80.3 and 82.3% for the spiked samples of 2.5 and 10 ppb, respectively. The relative standard deviation was 2.15% (n=ll). The results of this work confirm that the preparation method using microwave digestion provided the more advantages, such as rapid, a little volume of reagents, completely digestion.
机译:这项工作的目的是使用微波消解来验证样品制备,用于测定尖刺土中的总砷。石墨炉原子吸收分光光度计(GFAAs)技术用于测定使用硝酸钯作为改性剂的总砷。在干燥,灰化,雾化和清洁的条件步骤下分别进行仪器检测,分别为100,1200,2250和2600℃。外部校准曲线使用自动程序构造,具有20ppb砷解决方案的主标准。发现线性范围在1至20ppb的范围内,R〜2> 0。 LOD和LOQ分别为0.10和1.0 ppb。基于两个微波消解程序,还比较了从HF和不含HF的制备方法获得的总砷。结果表明,从两种方法获得的砷含量在95%的置信极限下没有显着差异。 2.5和10 ppb的尖峰样品分别为80.3和82.3%的百分比。相对标准偏差为2.15%(n = ll)。这项工作的结果证实,使用微波消解的制备方法提供了更快的优点,如快速,少量的试剂,完全消化。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号