首页> 外文会议>International Conference on Advanced Material and Manufacturing Science >Study on the Influence of Electrode Collocation to Electric Field Characteristic of ESP
【24h】

Study on the Influence of Electrode Collocation to Electric Field Characteristic of ESP

机译:电极搭配对ESP电场特性影响的研究

获取原文

摘要

A laboratory-scale ESP with new electrode configuration was established to investigate the electric field characteristic. Eight teeth prick line and prick plate with the length of 20mm were employed as discharge electrodes, respectively. The effects of discharge electrode type and electrode gap on V-I characteristic and surface current density were studied. The results showed that the optimum electrode gaps were 350-400mm for eight teeth line and 300-350mm for prick plate, which could obtained higher average current density and lower variance.
机译:建立了具有新电极配置的实验室标度ESP,以研究电场特征。八条齿刺线和长度为20mm的牵引板作为放电电极。研究了放电电极型和电极间隙对V-I特征和表面电流密度的影响。结果表明,最佳电极间隙为350-400mm,八个齿线和300-350mm用于刺盘,可以获得更高的平均电流密度和较低的方差。