首页> 外文会议>International Conference on 3D Radiation Dosimetry >Complexity metric based on fraction of penumbra dose - initial study
【24h】

Complexity metric based on fraction of penumbra dose - initial study

机译:基于Penumbra剂量分数的复杂性度量 - 初步研究

获取原文

摘要

Volumetric modulated arc therapy improve radiotherapy outcome for many patients compared to conventional three dimensional conformal radiotherapy but require a more extensive, most often measurement based, quality assurance. Multi leaf collimator (MLC) aperture-based complexity metrics have been suggested to be used to distinguish complex treatment plans unsuitable for treatment without time consuming measurements. This study introduce a spatially resolved complexity score that correlate to the fraction of penumbra dose and will give information on the spatial distribution and the clinical relevance of the calculated complexity. The complexity metric is described and an initial study on the correlation between the complexity score and the difference between measured and calculated dose for 30 MLC openings is presented. The result of an analysis of the complexity scores were found to correlate to differences between measurements and calculations with a Pearson's r-value of 0.97.
机译:与传统的三维保形放射治疗相比,体积调制的ARC治疗改善了许多患者的放疗结果,但需要更广泛,最常用的基于测量,质量保证。已经建议使用基于多叶准直器(MLC)光圈的复杂性度量来区分复杂的治疗计划,不适合治疗而不耗时测量。本研究引入了空间分辨的复杂性分数,与Penumbra剂量的分数相关,并将提供有关空间分布的信息和计算的复杂性的临床相关性。描述了复杂度度量,并提出了对复杂性评分与30mLC开口的测量剂量之间的相关性与30mLC开口之间的相关性之间的相关性的初步研究。发现复杂性分数的结果与Pearson的R值为0.97的测量和计算之间的差异相关。