Full scale experiments were performed in an underground subway station to investigate the effect of water mist on smoke flow from tunnel area to platform through shield door. Smoke temperature, species concentrations and smoke visibility were measured at different points. Dimensionless variables were introduced to represent the variations of smoke characteristics. The smoke temperature with water mist interaction could be reduced to less than 1/10 of the spill smoke flow. The mass flow rate could be reduced to less than 1/4 of the spill smoke flow. The experimental results indicated that the water mist system could help to reduce smoke temperature and the concentration of toxic species, improving survival conditions for evacuations of passengers.
机译:在地下地铁站中进行全规模实验,以调查水雾对通过屏蔽门从隧道区域到平台的烟雾流动的影响。在不同点测量烟雾温度,物种浓度和烟雾可见性。引入无量纲变量来表示烟雾特性的变化。具有水雾相互作用的烟雾温度可以降低到溢出烟雾的少于1/10。质量流量可以降低到溢出烟雾流量的小于1/4。实验结果表明,水雾系统有助于降低烟雾温度和有毒物种的浓度,改善乘客疏散的存活条件。