There is insufficient that get PT secondary voltage signal as a phase reference in capacitive device insulation online monitoring, in order to monitor the insulation accurately, this paper analyzes the advantages of using the relative measurement method for insulation monitoring, and determined the normal range of the dielectric loss by historical monitoring data and the number of failure equipment, furthermore positioned single or multiple faulty equipment by fault diagnosis matrix accurately. Finally, verified the effectiveness of the method by artificial simulation experiments in the laboratory.
机译:不足以使PT二次电压信号作为电容器件绝缘在线监测中的相位参考,为了准确监测绝缘,分析了使用相对测量方法的绝缘监测的优点,并确定了正常范围历史监测数据和故障设备数量的介电损耗,此外,通过故障诊断矩阵精确定位单个或多个故障设备。最后,通过实验室中的人工模拟实验验证了方法的有效性。