Experimental trials have been undertaken to determine interfacial area for mass transfer in 5cm and 25cm diameter annular centrifugal contactors. All trials used 30% TBP in Exxsol D80 diluent, with extraction of HNO_3 being studied at varying flowrates and volumetric flow ratios. Droplet size was determined using a laser reflectance probe. Results from the 5 cm rig showed two different regions of operation and the value of the dimensionless constant (K) in the Kolmogoroff expression was estimated to be 0.28 for O/A ratios below 2.5 and 0.30 above 2.5. From the 25cm rig trials K was estimated to be 0.26.
机译:已经进行了实验试验以确定5cm和25cm直径的环形离心接触器中的传质界面。所有试验在exxsold80稀释剂中使用30%Tbp,提取在不同流量和体积流量比下进行HNO_3。使用激光反射探针测定液滴尺寸。由5cm钻机的结果显示出两种不同的操作区域,并且Kolmogoroff表达中的无量子常数(k)的值估计为0.28,对于低于2.5和0.30以上2.5。从25厘米的钻机试验估计为0.26。