首页> 外文会议>International Conference on Material Sciences and Technology >Heat transfer of bottom tubes in delayed coking furnace: Simulation and measurement
【24h】

Heat transfer of bottom tubes in delayed coking furnace: Simulation and measurement

机译:延迟焦化炉中底管的热传递:仿真和测量

获取原文

摘要

Adding tubes on the bottom of delayed coking furnace is a useful measure for enhancing the throughput, but the distance between tubes and burners is too small to conform design standard. The security of these bottom tubes is uncertain. The processes of turbulence, combustion and heat transfer in the furnace were simulated by numerical method. Detailed information of velocity field, temperature field and heat flux was obtained. The heat transfer of tubes in entrainment zone of jet flame was investigated. The possibility of tube oxidation and hot spot was also discussed. Results show that the bottom tubes are security, which located in the low temperature field and the range of heat flux is 22~45 kW/m~2. The results are in good agreement with industrial testing data.
机译:延迟焦化炉底部添加管是增强吞吐量的有用措施,但管和燃烧器之间的距离太小而无法符合设计标准。这些底管的安全性是不确定的。通过数值方法模拟炉中湍流,燃烧和传热的过程。获得了速度场,温度场和热通量的详细信息。研究了喷射火焰夹带区域中的管的热传递。还讨论了管氧化和热点的可能性。结果表明,位于低温场中的底管是安全性,热通量范围为22〜45 kW / m〜2。结果与工业测试数据吻合良好。