Evaluating Color Shift in Liquid Crystal Displays with the Primary Stability Metrics

机译:评估液晶显示器的颜色换档,主要稳定度量显示

获取原文

摘要

One of the major issues that obstruct the consistency and interoperability of medical color LCDs is the challenge of accurately characterizing and modeling the LCD color response. The challenge originates from the instability of the primaries - the chromaticity of primaries varies with the digital driving level. The primary instability also manifests itself in other forms such as color gamut shrinkage, color shift, gray imbalance, and contrast reduction. In this paper we describe a quantitative metric, primary stability, for measuring the stability of the primaries. Two metrics were then derived from primary stability to measure the color shift of a display: (a) the area-between-curves metric measures gray imbalance, and (b) the area-under-curve metric measures the reduction in color gamut. Characterization data from 9 displays are used to demonstrate the capability of the primary stability-based metrics.
机译:阻碍医用颜色LCD的一致性和互操作性的主要问题之一是准确表征和建模LCD颜色响应的挑战。挑战源自初始的毫无稳定性 - 初选的色度随数字驾驶水平而变化。初级不稳定性也以其他形式表现出颜色域收缩,颜色偏移,灰色不平衡和对比度。在本文中,我们描述了定量的公制,主要稳定性,用于测量初学的稳定性。然后从初级稳定性导出两个度量来测量显示器的颜色偏移:(a)区域 - 曲线度量测量灰色不平衡,并且(b)面积曲线测量测量颜色域的减少。来自9个显示器的特征数据用于展示基于初级稳定性的度量的能力。