Process-Utility Interaction Analysis for a True Energy Saving Value Determination

机译:真实节能值确定的过程 - 实用性交互分析

获取原文

摘要

This paper shares the experience of Saudi Aramco's energy assessment team in finding a true energy saving potential from one of Aramco's oil and gas plants. It involves a comprehensive energy assessment of both the process and utility section of the plant simultaneously. In the case of process energy saving assessment, pinch analysis together with other process improvement tools (e.g., process simulation analysis), is normally used to identify the energy saving opportunities. During this analysis, no value of energy saving (/year) is determined but rather the analysis only focuses on the amount of savings in both heating and cooling loads. During this stage too, the team highlights the pros and cons of such energy saving initiatives, which includes the proposed project cost estimates, operability aspects and safety considerations. In a separate task, the utility team uses an in-house utility modeling tool to assess energy performance of the existing utility system. The advantage of having such a model is not only for its ability to optimize the existing utility performance but also the ability to "link" or interact with our energy saving findings from the process section. For example, the team can then see clearly the full impact of reducing the heating load in the process on the performance of the utility system itself. Hence, this allows the true energy saving value to be determined from the overall performance of the utility system. Once the true energy saving potential has been determined for each of the identified opportunities, the proposed projects can then be prioritized according to the common decision criteria, like economics, operability and safety. A case study from one of Saudi Aramco's NGL fractionation facilities will be used to demonstrate the approach highlighted in this paper.
机译:本文分享沙特阿美能源评估小组的经验,以找到来自阿美峡和天然气植物之一的真正节能潜力。它涉及同时植物的过程和实用部分的全面能源评估。在过程节能评估的情况下,与其他过程改进工具(例如,过程仿真分析)一起捏合分析,通常用于识别节能机会。在此分析期间,确定节能(/年)的价值,而是分析仅关注加热和冷却负荷的节省量。在此阶段也,该团队强调了这种节能举措的利弊,包括拟议的项目成本估计,可操作性方面和安全考虑。在一个单独的任务中,该实用程序使用内部实用建模工具来评估现有公用事业系统的能量性能。具有这样的模型的优点不仅可以优化现有公用事业性能,而且可以从过程部分与我们的节能结果相互作用的能力。例如,该团队可以清楚地看到减少加热负荷在工艺本身的性能过程中的完全影响。因此,这允许从公用事业系统的整体性能确定真正的节能值。一旦针对每个所确定的机会确定了真正的节能潜力,就可以根据共同的决策标准,如经济学,可操作性和安全性,所以可以优先考虑所提出的项目。 Saudi Aramco的NGL分级设施之一的案例研究将用于展示本文突出的方法。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利