SONAR-Based Gas Void Fraction Measurement Improves Coriolis and Turbine Flowmeter Performance in Multiphase Flows (0-10percent GVF)

机译:基于声纳的气体空隙分数测量可提高Coriolis和涡轮机流量计在多相流动中的性能(0-10-10percent GVF)

获取原文

摘要

Test data confirms that turbine and Coriolis meters over-report the volumetric flow rate in proportion to the amount of entrained gas. Using the gas void fraction measurement of the SONAR-based system provides a simple correction to the primary measurement of both flowmeter technologies to within +-1percent of the reference liquid flow rate for 0-10percent GVF range. The Coriolis meter under test correctly measured the mixture (liquid + gas) density within +-1percent of the reference, independent of entrained gas levels. Liquid density is required to determine water-cut and in this test it was calculated by correcting the measured mixture density for gas void fraction. Using a simple GVF correction, the liquid density was reported to within +-1percent for 0-10percent GVF.
机译:测试数据确认涡轮机和科里奥利米过度报告与夹带的气体量成比例的体积流量。使用基于声纳的气体空隙率测量,提供了对流量计技术的主要测量来到+ -1 -1的初级测量的简单校正,用于0-10percent GVF范围。正在测试的科里奥利仪表正确地测量了在参考的+ -1平方内的混合物(液体+气体)密度,与夹带的气体水平无关。需要液体密度来确定水切割和在该测试中,通过校正测量的气体空隙级分的混合密度来计算。使用简单的GVF校正,将液体密度报告为0-10percent GVF内的+ -1°。