首页> 外文会议>International Conference on Structural Dynamics >Shaking Table Test of the Effects of Particle Dampers Attached to a Multi-Degree-of-Freedom System. Part 1: Experimental study
【24h】

Shaking Table Test of the Effects of Particle Dampers Attached to a Multi-Degree-of-Freedom System. Part 1: Experimental study

机译:振动表试验颗粒阻尼器附着在多程度自由度系统的效果。第1部分:实验研究

获取原文

摘要

This paper presents the results of an experimental study of the performance of multi-unit particle dampers with a multi-degree-of-freedom system under earthquake excitations. A series of shaking table tests of a three-storey steel frame with the particle damper system are carried out to evaluate the performance of the system. The experimental results indicate that the frame with particle dampers has smaller response compared with that of the frame without particle dampers;;that the excitation characterization influences the performance of particle damper system;;and that the particle movements of plug flow pattern can yield good vibration attenuation effects. It is shown that by using a properly designed multi-unit particle dampers, a lightly damped primary system can achieve a reasonable reduction in its response, with a small weight penalty.
机译:本文介绍了在地震激励下具有多程度自由度系统的多单元粒子阻尼器的实验研究的实验研究。进行了一系列带有粒子阻尼系统的三层钢框架的振动台测试,以评估系统的性能。实验结果表明,与没有粒子阻尼器的框架相比,具有粒子阻尼器的框架具有较小的反应;;激励表征会影响粒子阻尼系统的性能;塞流模式的粒子运动可以产生良好的振动衰减效果。结果表明,通过使用适当设计的多单元粒子阻尼器,轻微阻尼的主要系统可以在其响应中实现合理降低,重量罚款小。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有