首页> 外文会议>Cryogenic Engineering Conference >Thermal Conductivity Measurements of Subcooled Oxygen below 80 K
【24h】

Thermal Conductivity Measurements of Subcooled Oxygen below 80 K

机译:氧化氧的导热率测量低于80 k

获取原文

摘要

The first thermal conductivity measurements of liquid oxygen at temperatures below 80 K, and at pressures up to 1 MPa are reported. The measurements were conducted in a horizontal, guarded, flat plate calorimeter, and are based on the steady-state approach. The cooling power to the calorimeter is provided by a Gifford-McMahon type cryocooler. The temperature difference between the plates of the calorimeter and the absolute temperature are measured using calibrated platinum thermometers. One dimensional heat transfer between the hot and cold plates of the calorimeter is achieved by placing two thermal guards, instrumented with heaters and platinum thermometers, around the hot plate. Although used exclusively for measurements with oxygen, this apparatus is capable of measuring the thermal conductivity of other fluids including liquid hydrogen down to about 15 K.
机译:报道了在低于80k的温度下的液氧的第一导热率测量,并且报告高达1MPa的压力。测量在水平,保护的平板热计中进行,并基于稳态方法。热量计的冷却功率由Gifford-McMahon型冷冻室提供。使用校准的铂温温度计测量量热计的板和绝对温度之间的温度差。通过将两个热防护装置置于热板周围的热防护装置,通过涂有两个热防护剂,仪器,通过涂有两个热防护剂来实现热和冷板之间的一维传热。尽管专门用于用氧气进行测量,但该装置能够测量其他流体的导热率,包括液体氢气下降至约15k.