首页> 外文会议>International Conference on Synchrotron Radiation Instrumentation >Interferometric phase-contrast X-ray CT imaging of VX2 rabbit cancer at 35keV X-ray energy
【24h】

Interferometric phase-contrast X-ray CT imaging of VX2 rabbit cancer at 35keV X-ray energy

机译:在35KeV X射线能量下Vx2兔癌的干涉性相位对比X射线CT成像

获取原文

摘要

Imaging of large objects at 17.7-keV low x-ray energy causes huge x-ray exposure to the objects even using interferometric phase-contrast x-ray CT (PCCT). Thus, we tried to obtain PCCT images at high x-ray energy of 35keV and examined the image quality using a formalin-fixed VX2 rabbit cancer specimen with 15-mm in diameter. The PCCT system consisted of an asymmetrically cut silicon (220) crystal, a monolithic x-ray interferometer, a phase-shifter, an object cell and an x-ray CCD camera. The PCCT at 35 keV clearly visualized various inner structures of VX2 rabbit cancer such as necrosis, cancer, the surrounding tumor vessels, and normal liver tissue. Besides, image-contrast was not degraded significantly. These results suggest that the PCCT at 35 KeV is sufficient to clearly depict the histopathological morphology of VX2 rabbit cancer specimen.
机译:即使使用干涉式相位对比度X射线CT(PCCT)也使大物体的大物体的成像导致巨大的X射线暴露于物体上。因此,我们尝试在35kev的高X射线能量下获得PCCT图像,并使用福尔马林固定的Vx2兔癌标本检查直径为15毫米的福尔马林固定的Vx2兔癌样品。 PCCT系统由不对称切割的硅(220)晶体,单片X射线干涉仪,移相器,物体单元和X射线CCD相机组成。 PCCT在35 keV下清晰可视化了Vx2兔癌的各种内部结构,如坏死,癌症,周围的肿瘤血管和正常肝组织。此外,图像对比度没有显着降低。这些结果表明,35keV的PCCT足以清楚地描绘Vx2兔癌标本的组织病理学形态。