A portable stretching device with intelligent control was developed to treat the spastic/contractured ankle of neurologically impaired patients and evaluate the outcome. The device stretched the ankle throughout the range of motion (ROM) to extreme dorsiflexion and plantar flexion until a specified peak resistance torque was reached with the stretching velocity controlled based on the resistance torque. Stretching velocity was adjusted constantly. It was slow at the joint extreme positions, making it possible to reach a larger ROM safely, and it was fast in the middle ROM so the majority of the treatment was spent in stretching the problematic extreme ROM. The ankle was held at the extreme position for a period of time to let stress relaxation occur before it was rotated back to the other extreme position. Furthermore, the device evaluated treatment outcome quantitatively in multiple aspects, including active and passive ROM, joint stiffness and viscous damping, and reflex excitability. Combined with ultrasonography, the device was used to evaluate changes in mechanical properties of the Achilles tendon-aponeurosis induced by the stretching. The intelligent stretching reduced spasticity and contracture, including increases passive and active ROMs, decreases in elastic stiffness and viscous damping, and increase in muscle force-generating capacity.
机译:与智能控制的便携式拉伸装置被开发用于治疗神经功能受损患者的痉挛/ contractured脚踝和评估结果。该装置在整个拉伸运动(ROM)极端背屈和跖屈的范围脚踝直到指定的峰阻力转矩与基于上述阻力矩控制的拉伸速度达到。拉伸速度恒定地调节。这是一个在合资极限位置缓慢,使其能够安全地到达一个更大的ROM,并在中间ROM是快,所以大多数治疗的拉伸问题的极端ROM花了。脚踝是在一段时间内让应力松弛发生之前,这是转回到另一个极端位置的极端位置上。此外,该装置在多个方面,包括主动和被动ROM,关节僵硬和粘性阻尼,和反射性兴奋定量评价治疗效果。用超声结合,所述装置用于评价由拉伸引起的跟腱-腱膜的机械性质的变化。智能拉伸降低痉挛和挛缩,包括增大的无源和有源ROM的,在弹性刚度和粘性阻尼,并在力产生肌肉能力的增加而降低。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号