Evaluation and Calibration of PET Scanners with a Specially Designed Point-like Radioactive Source

机译:具有专门设计的点放射源的PET扫描仪的评估和校准

获取原文

摘要

Background: In order to evaluate the uncertainty in the radioactivity measurements performed using PET scanners and to determine the calibration factors of these scanners, it is essential that the radioactive sources are equipped with absorber materials that ensure the annihilation of positrons. Therefore, the evaluation and calibration depend on scatter and attenuation corrections in conventional techniques based on phantoms. Although an extrapolation method that involves the use of multiple absorber sleeves for a line radioactive source is effective in eliminating the dependence, the long line shape limits its application range. Objective: The objective of this study is to propose a point-like radioactive source with multiple absorber capsules, which can be used to evaluate the uncertainty in the radioactivity measurements performed using a PET scanner and to determine a calibration factor in a way that is independent of scatter and attenuation corrections. Methods: The proposed radioactive source consists of a small spherical radioactive part and a set of successively sized aluminum absorber capsules. Extrapolation over the total absorber thickness made it possible to estimate the results that were approximately free from scatter and absorption caused by the absorber materials. As an example application, the proposed method was used to a research PET scanner. In addition, the basic characteristic of the point-like radioactive source was investigated using a Monte Carlo simulation code. Results and Conclusion: Performance characteristics and a calibration factor of the PET scanner were successfully evaluated and determined. Therefore, the proposed method is useful for this purpose. Further studies are expected to improve the design of the radioactive source and enhance the practicability and traceability of our proposed method.
机译:背景:为了评估使用PET扫描仪进行的放射性测量中的不确定性,并确定这些扫描仪的校准因子,因此必须提供放射源的吸收材料,以确保积极的湮灭。因此,评估和校准依赖于基于幽灵的传统技术中的散射和衰减校正。尽管涉及使用多个吸收器套管的外推方法对于线放射源的使用是有效的,但是在消除依赖性方面有效,但是长线形状限制其应用范围。目的:本研究的目的是提出具有多个吸收胶囊的点状放射源,其可用于评估使用PET扫描仪进行的放射性测量中的不确定性,并以独立的方式确定校准因子分散和衰减校正。方法:所提出的放射源包括小球形放射性部分和一组连续尺寸的铝吸收胶囊。在总吸收体厚度上的外推使得可以估计由吸收材料引起的散射和吸收的结果。作为示例应用程序,所提出的方法用于研究PET扫描仪。此外,使用蒙特卡罗仿真代码研究了点状放射源的基本特征。结果和结论:成功评估了PET扫描仪的性能特性和校准系数。因此,所提出的方法对此目的是有用的。预计进一步的研究将改善放射源的设计,并提高我们提出的方法的实用性和可追溯性。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号