Endovascular stents can be altered to improve radioopacity by applying a gold coating. We examined the vascular response in porcine coronary arteries to implantation of 9 mm NIR stents that were either left intact, gold-coated, or heat-treated following gold coating. Our results show that while gold coating exacerbates neointimal hyperplasia and the inflammatory response, heat treatment removes this negative effect. Heat treatment was shown to increase the diffusion at the gold-steel interface and reduce the surface roughness.
机译:通过施加金涂层可以改变血管内支架以提高放射性不透程性。我们检查了猪冠状动脉中的血管反应,以植入9mM的涂层,其留下完整,镀金或在金涂层后进行热处理。我们的研究结果表明,虽然金涂层加剧新内膜增生和炎症反应,但热处理消除了这种负面影响。显示热处理以增加金钢界面的扩散并降低表面粗糙度。