首页> 外文会议>Joint ASME/JSME Pressure Vessels and Piping Conference >EVALUATIOM OF ISOLATION VALVE LEAKAGE IN ALTERNATE CHARGING PIPING
【24h】

EVALUATIOM OF ISOLATION VALVE LEAKAGE IN ALTERNATE CHARGING PIPING

机译:交替充电管道中隔离阀泄漏的评价

获取原文

摘要

The chemical and volume control system (CVCS) alternate charging flow path at an operating pressurized water reactor (PWR) plant was determined to be susceptible to adverse stresses from isolation valve leakage. Isolation valve leakage had resulted in pipe cracks at several nuclear units worldwide, as described in United States Nuclear Regulatory Commission Bulletin 88-08 and its supplements. To provide for continuing assurance that cracks would not initiate over the plant life, the operators considered performing fatigue evaluation to demonstrate structural integrity of the system. This evaluation included heat transfer, stress and fatigue analysis, using methods described in Electric Power Research Institute Report "Thermal Stratification, Cycling, and Striping (TASCS)," March 1994. The evaluation concluded that the fatigue usage would be less than 1.0 under worst case isolation valve leakage conditions, and therefore a significant investment in permanent temperature monitoring was avoided.
机译:化学和容积控制系统(CVCS)另一种加料流路在操作压水反应堆(PWR)的植物被确定为易患从隔离阀的泄漏不良应力。隔离阀泄漏已导致全球在几个核电机组管道裂缝,如在美国核管理委员会公告88-08及其补充说明。为了提供持续的保证,裂缝不会启动通过植物的生命,运营商考虑进行疲劳评估,以表明该系统的结构完整性。本评价包括热传递,压力和疲劳分析,采用方法电力研究所报告描述“热分层,自行车,和条带化(TASCS),” 1994年3月的评价的结论是,疲劳损耗将小于1.0在最坏因此情况下隔离阀泄漏的条件下,并避免了永久温度监测一个显著投资。