To improve the ignition and combustion performance of a 600MW supercritical down-fired boiler (DFB) equipped with slot burners, some retrofits on the burners and associated concentrators were conducted. Comparative measurements on the performance of concentrators, and temperatures in the zones of burner and hopper were measured before and after the retrofit under different operation settings. Results revealed that before retrofit though in general the fuel-rich coal/air mixture could be ignited within the distance of 2.5m, the ignition of the fuel-lean coal/air flows was poor. For all burners, ignition was postponed with the increasing secondary air. After retrofit, carbon content in fly ash and slag decreased by improving the primary air separation devices, air distribution and nozzle structure design. The ignition distance of the fuel-rich flows and the depth of flame traveling path became remarkably shorter, and flame temperature in the hopper region decreased. The combustion stability and efficiency of the boiler were improved.
机译:为了提高配备有槽燃烧器的600MW超临界筒式锅炉(DFB)的点火和燃烧性能,对燃烧器和相关的集中器进行了一些改造。在不同操作环境下改造之前和之后测量燃烧器和料斗区域的性能的比较测量,以及燃烧器区域的温度。结果表明,在改造之前,虽然一般来说,富含燃料的煤/空气混合物可以在2.5米的距离内点燃,燃料瘦煤/空气流的点火差。对于所有燃烧器,点火被推迟随着增加的二次空气。在改造后,通过改善主空气分离装置,空气分布和喷嘴结构设计,粉煤灰和炉渣中的碳含量降低。富含燃料流的点火距离和火焰行进路径的深度变短,并且料斗区域中的火焰温度降低。锅炉的燃烧稳定性和效率得到改善。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号